Page 170 - Workshop Manual - Tunland (2017)
P. 170

04-32                  DIAGNOSTICS - ANTI-LOCK BRAKING SYSTEM (ABS)

                                                      (a)    Turn off the ignition switch and disconnect the
                                                             connector C013 of the combination
                                                             instrument.
                                                      (b)    Measure the resistance between the pin 17
                                                             of connector C013 of the combination
                   C013       16 15  14  13 12  11 10  9  8  7  6  5  4  3  2  1
                              32 31  30  29 28 27  26  25  24  23  22  21  20  19  18 17  instrument and the pin 26 of the connector
      04
                                                             A006 of ABS control module.
                                                             Standard resistance

                                                         Connection of the
                                                                                      Standard value
                                                             multimeter
               13  12  11  10  9  8  7  6  5  4  3  2  1
                  24  23  22  21  20 19  18  17 16  15  14  A006
               38  37  36  35  34  33  32  31  30  29  28  27  26  25  C013(17)-A006       <2Ω
                                            ftwxd041347        (26)


                                                      (c)    Measure the resistance between the pin 1 of
                                                             connector C013 of the combination instrument
                                                             and the pin 14 of the connector A006 of ABS
                                                             control module.
                                                             Standard resistance
                              16 15  14  13 12  11 10  9  8  7  6  5  4  3  2  1
                   C013
                              32 31  30  29 28 27  26  25  24  23  22  21  20  19  18 17
                                                         Connection of the
                                                                                      Standard value
                                                             multimeter
                                                       C013(1)-A006(14)                    <2Ω



               13  12  11  10  9  8  7  6  5  4  3  2  1
                  24  23  22  21  20 19  18  17 16  15  14  A006
               38  37  36  35  34  33  32  31  30  29  28  27  26  25
                                            ftwxd041348

           Check whether the result is normal?
           Yes > Maintain or replace the combination instrument.

           No > Maintain or replace the harness and connectors
   165   166   167   168   169   170   171   172   173   174   175