Page 2064 - Workshop Manual - Tunland (2017)
P. 2064
61-58 HEATER AND AIR CONDITIONING - A/C VALVE MOTOR
(b) Connect the mode valve motor connector.
61
ftwx611031
8 . Install the Circulation Valve Motor
(a) Install the circulation valve motor and tighten
the retaining bolts.
ftwx611030
(b) Connect the circulation valve motor connector.
ftwx611029
9 . Install the dashboard. (Refer to "Chapter 83. Dashboard/instruments - instrument
panel, replacement")
10 . Connect battery negative cable. (Refer to "Chapter 20. Start & charge - battery,
replacement")