Page 259 - Workshop Manual - Tunland (2017)
P. 259

DIAGNOSTICS - REVERSE RADAR SYSTEM                           04-121

                 Check whether the result is normal?

                 Yes> go to step 3
                 No> replace reverse switch

                 3 .    Check the harness and connector (ignition switch-fuse)
                 (a)    Ignition Switch: OFF.                                                                        04


                                                           (b)    Measure the electrical resistance between
                                                                  indoor fuse box F31 (7.5A) and the ignition
                                                                  swith.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)


                                                            Multimeter connection          Standard value
                                                              F31 (7.5A) - Ignition
                                                                      switch                     <2Ω









                 Check whether the result is normal?

                 Yes> go to step 4
                 No > Maintenance or replace harness.

                 4 .    Check the harness and connector (fuse- reverse switch)

                 (a)    Ignition Switch: OFF.
                 (b)    Disconnect reverse switch connector K002.


                                                           (c)    Measure the electrical resistance between
                                                                  reverse switch connector K002(1) and indoor
                                                                  fuse box F31(7.5A).

                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                               F31(7.5 A) - K002                 <2Ω
                                                                      (1)









                 Check whether the result is normal?

                 Yes> go to step 5
   254   255   256   257   258   259   260   261   262   263   264