Page 268 - Workshop Manual - Tunland (2017)
P. 268

04-130                      DIAGNOSTICS - REVERSE RADAR SYSTEM

                                                      (e)    Measure the electrical resistance between
                                                             left reverse radar probe connector B006(1)
                                                             and reverse radar controller connector C035
                                                             (31).
                                                             Standard electrical resistance (check

      04                                                     whether there existent an open circuit)
                                                       Multimeter connection          Standard value

                                                       C035(31)- B006(1)                   <2Ω









           Check whether the result is normal or not?
           Yes>Replacement reverse radar controller)
           No > Maintenance or replace harness.
   263   264   265   266   267   268   269   270   271   272   273