DIAGNOSTICS - WIPER & WASHER                             04-257

                                                           (c)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                               A007
                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                               A 007 (4) - ground               < 2 Ω









                                                 ftwxd041362


                 Check whether the result is normal?
                 Yes> go to next step.
                 No > Maintain or replace the harness


                 3 .    Check the harness and connectors (wiper and washer switch - ground)
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector C012 of
                                                                  combination switch (wiper).














                                                 ftwx641020

                                                           (c)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)


                                               C012         Multimeter connection          Standard value
                                                               C012 (3) - ground                < 2 Ω










                                                 ftwxd041363