Page 430 - Workshop Manual - Tunland (2017)
P. 430
04-292 DIAGNOSTICS - AIR CONDITIONING SYSTEM
DEFECT PHENOMENON FORM
Check the table below to find the cause of the problem. The numbers rank the possibility of
the causes. Check each part in this order and replace the part if necessary.
Defect phenomenon Suspect Area Reference
04 1. Fuse -
2. Relay -
No function of the air Chapter 61. Heating & A/C - evapora-
3. Air condition magnifier
conditioning system tor, replacement
works Chapter 61. Heating & A/C - A/C
4. A/C compressor
compressor, replacement
5. Harness -
1. Fuse -
2. Relay -
Chapter 61. Heating & A/C - blower,
3. Blower switch
replacement
4. Governing resistor of Chapter 61. Heating & A/C - blower,
Air output control:
blower replacement
Blower does not work
Chapter 61. Heating & A/C - blower,
5. Blower motor
replacement
Chapter 61. Heating & A/C - control
6. Air conditioner controller
mechanism, replacement
7. Harness -
Chapter 61. Heating & A/C - blower,
1. Blower switch
replacement
2. Governing resistor of Chapter 61. Heating & A/C - blower,
blower replacement
Chapter 61. Heating & A/C - blower,
Air output control: Air 3. Blower motor replacement
exhaust is inadequate
Chapter 61. Heating & A/C - control
4. Air conditioner controller
mechanism, replacement
Chapter 61. Heating & A/C - instru-
5. Front air outlet
ment board air passage, replacement
6. Harness -