04-288 DIAGNOSTICS - AIR CONDITIONING SYSTEM
BASIC INSPECTION
Steps Inspection contents Measures
Check for Yes No> go to step 2
refrigerant.
04 • Screw off the
protective cap of
maintenance valve
1 of air condition
refrigeration No? Add refrigerant.
system, and push
the valve core.
Check whether the
result is normal?
Check the air Yes No> go to step 3
condition switch.
• Turn on the air
conditioner
• Check in a visual
2 manner whether the to Defect
air conditioner No? Phenomenon Form
operating indicator
lamp goes on.
Check whether the
result is normal?
Check the magnetic Yes No> go to step 4
clutch.
• Check the magnetic
3 clutch for normal to Defect
engagement. No? Phenomenon Form
Check whether the
result is normal?
Check the drive belt. Yes No> go to step 5
• Check the drive belt
4 for slippage. to Defect
No?
Check whether the Phenomenon Form
result is normal?
Check the Yes No> go to step 6
compressor.
• Check whether any
5 abnormal sound to Defect
No?
may be heard Phenomenon Form
during operation of
the compressor.