Page 423 - Workshop Manual - Tunland (2017)
P. 423
DIAGNOSTICS - WIPER & WASHER 04-285
(d) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
C012 A015 whether there existent an open circuit)
Multimeter connection Standard value
04
A015 (2)–C012(6) < 2 Ω
ftwxd041380
Check whether the result is normal?
Yes> go to step 4
No > Maintenance or replace harness.
4 . Check the harness and connectors (front washer motor - ground)
(a) Ignition Switch: OFF.
(b) Disconnect the connector A015 of front
washer motor.