Page 474 - Workshop Manual - Tunland (2017)
P. 474

04-336                           DIAGNOSTICS - AUDIO SYSTEM

                                                      (b)    Use a multimeter to measure the resistance
                                                             between pin 4 of connector C044 of acoustics
                                                             unit and the ground.
                                                             Standard resistance (check whether there
                                                             is short circuit)

      04                                               Multimeter connection          Standard value

                                                          C044(4) - ground                >1MΩ











           Check whether the result is normal?
           Yes > Go to step 3.
           No > Replace fuse: F22 (7.5A), and repair the to-earth short-circuit of circuit from fuse
           F22 (7.5A) to pin 7 of connector C044 of acoustics unit.


           3 .    Check the acoustics unit module

                                                      (a)    Disconnect the battery negative cable,
                                                             disconnect the connector C044 of the
                                                             acoustics unit.

                                                           CAUTION

                                                      Be careful not to drop the acoustics unit.