04-420                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (f)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
      04
                                                          A004 (2) - ground
                                                          B005 (1) - Ground               < 2 Ω

                                                          G002 (2) - ground
















           Check whether the result is normal?

           Yes> go to step 6
           No > Maintenance or replace harness.

           6 .    Check the combination switch (lamplight switchover)

           (a)    Ignition Switch: OFF.

                                                      (b)    Disconnect the connector C008 of
                                                             combination switch (lamplight switchover).