Page 559 - Workshop Manual - Tunland (2017)
P. 559

DIAGNOSTICS - LIGHTING SYSTEM                            04-421

                                                           (c)    Check the combination switch (lamplight
                                                                  switchover)
                                                                  Standard resistance:

                                                                                Multimeter
                                                                                                   Specified
                                                              Conditions        connection
                                                                                                     value
                                                                                   stitch                            04
                                                              Turn off the
                                                                                   18-19            ≥ 1 MΩ
                                                            right turn switch

                                                              Turn on the
                                                                                   18-19             < 2 Ω
                                                            right turn switch





                 Check whether the result is normal?
                 Yes> go to step 7
                 No > Replace the combination switch.


                 7 .    Check the harness and connectors (combination switch - ground)
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector C008 of
                                                                  combination switch (lamplight switchover).














                                                 ftwx641019

                                                           (c)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                 C008
                                                            Multimeter connection          Standard value
                                                               C008 (19) - ground               < 2 Ω










                                                 ftwxd041390