R.4   Generally (cont'd)

                     4.    Connecting cabie ends or cable tails shall be deemed to be included with the item. Cable
                          termination glands shall be given in accordance with claUse R.15.6.

                     5.    Platework and supporting steelwork shall be given in accordance with Section P.

               R.5  Equipment supports

                     1.    Equipment supports shall be enumerated and described.

                     2.    Particulars of the method of hxing shall be given in the description in accordance with
                          clauses R.1.5-6.

                     Fittings and accessories

               R.6  Generally

                     1.   Unless othenwise stated fittings (e.g. clocks, telephones, alarm bells and loud speakers)
                          and accessories (e.g. Iighting switches, socket outlets, connection units, thermostats,
                          telephone cord outlet points, bell pushes and other similar units associated with final
                          circuits) shall be enumerated.

                     2.   Boxes, conduit boxes, patterae, ceiling roses, connector blocks, flexible cords, starters,
                          lamp holders and the like shall be given in the description.

                     3.   Bushes, nipples, lock nuts and connecting the cables tails shall be deemed to be included
                          with the items.

                     4.   Fixing fittings provided by the Employer shall be enumerated stating the type and size.
                          Accepting delivery, storing and handling the fittings and connecting the cable-tails shall be
                          deemed to be included with the items. Providing any additional material and internal wiring
                          required shall be given in the description. Where an item of fixing involves handling an
                          ornamental or unusually expensive fitting, particulars of the character and value shall be
                          given in the description.

               R.7  Lighting fittings

                     1.    Pendant fittings shall be enumerated stating the length of the pendant drop in stages of
                          300mm.

                     2.    Cold cathode fittings and connecting to the circuit wiring shall be given as a provisional or
                          prime cost sum.

               R.8   Accessories

                     Accessories shall be enumerated in gangs stating the rated capacity and the type of each
                     accessory and the number of accessory in each gang.