Page 114 - SMM2 eBOOK
P. 114

R.19  Conductors (cont'd)

                     2.   Conductor connections and junctions shall each be enumerated separately stating the
                          type and size of the conductor. Tinning, sweating and providing any jointing materials,
                          heat, holes, rivets, bolts, nuts, washers and clamps shall be deemed to be included.

                     3.   All bends shall be deemed to be included with the items.

                     4.   Test-clamps shall be enumerated stating the type, the size and the method of connecting.

                     5.   Earth-electrodes shall be enumerated stating the type and size. Driving electrodes into
                          ground shall be given in the description. Connecting electrodes to conductors shall be
                          deemed to be included.

                     6.   Air-termination points shall be enumerated stating the type, the size and the method of
                          connecting.

                     Ancillaries

               R.20  Loose ancillaries

                     Loose keys, tools, spares and the like shall each be enumerated separately stating the type and
                     quantity. Rack for holding tools and the like shall be described and enumerated.

               R.21  Identification Plates

                     Plates, discs and labels for the identification of plants, cables, switches and the like shall be
                     deemed to be included with the item concerned. Charts giving the key thereto shall be
                     enumerated.


                     Sundries

               R.22  Generally

                     1.   Marking the positions of holes, mortices, chases and the like in the structure shall be
                          given as an item for each installation. Where the nature of the work necessitates any of
                          those to be formed during construction, the relevant particulars shall be given.

                     2.   General earth bonding and earthing each installation shall be given as an item.

                     3.   Disconnecting, seKing aside and rehxing existing equipment for the convenience of other
                          trades shall be given as an item stating the relevant particulars.

                     4.   Temporarily operating each installation (except for testing) shall be given as an item
                          stating any required qualifications of the aKendant, the duration of the operating period in
                          hours and the purpose and particulars of any special insurance cover required by the
                          Employer. Providing current shall be deemed to be included with the items.

                     5.   Testing each installation shall be given as an item stating particulars of any special
                          insurance cover required by the Employer Providing instruments  and current shall be
                          deemed to be included.









                                                           111