Page 80 - SMM2 eBOOK
P. 80
L.48 Flashings (cont’d)
4. Dressing over glass and glazing bars, corrugated roofing, Roman tiling, pantiling and
similar materials shall be given in the description stating whether along or across the bars
or corrugations.
5 Ends, angles and intersections to cappings, hollows, condensation channels and
mouldings shall be deemed to be inciuded.
L.49 Preformed flashings
Preformed flashings, aprons, cappings and the like shall each be given separately in metres
stating the profile in accordance with clause L.47 and the method of jointing. Angles and
returned ends shall each be enumerated separately. Stopped ends shall be deemed to be
included with the items
L.50 Flat gutters
Linings to parapet gutters and to other flat gutters requiring drips and rolls shall be given in
accordance with clause L.51.
L.51 Sloping gutters
1. Linings to sloping gutters shall be given in metres stating the profile in accordance with
clause L.47.
2. Dressings over tilting-fillets, wedging into grooves and the like labours shall be given in
the description.
3. Bossed, burned and brazed ends and angles, dressing through outlets, dressing into
rainwater heads and the like labours shall be deemed to be included in the items.
L.52 Soakers and metal slates
Soakers and metal slates shall each be enumerated separately stating the size. Collars around
pipes shall be given in the description of the metal slates stating the size and kind of pipe and
the method of jointing thereto.
L.53 Saddles
Saddies over abutments and intersections of hips and ridges (grouped together) shall be
enumerated stating the size of the metal. Dressing and bossing shall be given in the description.
77