200   Nuclear Science and Technology | Progress Report





               by thermal treatment at 1600°C for 4h. As      chambers. Lower detection limit, detection sen-
               sintered yttria based rods exhibited dense     sitivity and signal response repeatability of the
               surface microstructure, homogeneous size,      Fricke gel solution for the measuring methods
               shape, and cleavage planes characteristics of   was determined. The stability of the different
               transgranular fracture, as illustrated in Fig.34.   computerized tomography equipment with
               Furthermore, doping yttria with europium       multiple detectors was also evaluated. The Fric-
               (Y O :Eu) led to formation of new defects,     ke gel solution presented repeatability better
                 2  3
               which in turn, supplied more effective EPR re-  than + 5.5% using the O.A. spectrophotometry
               sponse. Y O :Eu rods exhibited linear EPR dose   technique and + 3.5% using MRI technique. The
                        2  3
               response-behavior from 0.001 up to 10kGy.      CT equipment presented repeatability better
               Thermal fading of EPR signal was less than     than + 0.2%. A skull phantom filled with the
               20% during 162h. Complete cleaning of EPR      Fricke gel solution was developed to determine
               signal was achieved by thermal treatment at    the total collimation of the CT equipment and
                    o
               1000 C/2h in air. These innovative results show   the dose distribution using the three-dimen-
               that rare earth based ceramics are promising   sional magnetic resonance imaging technique.
               materials for dosimetry.                       The Fricke gel solution is easy and relatively
                                                              quick to prepare, but care must be taken to
                                                              avoid contamination and lose the solution. The
                                                              results obtained confirmed the application of
                                                              this type of dosimetry to the CT equipment.

                                                              Metrology in Radiotherapy


                                                              TL response and intrinsic efficiency of
                                                              dosimeters irradiated using different phantoms
                                                              in clinical electron beam dosimetry


                                                               Different phantom materials affect the elec-
               Figure 34. SEM images of Y O :Eu rods sintered at 1600°C
                                2  3
               for 4h at room atmosphere, (a) general view of ceram-  tron spectrum incident on the detector and it
               ic rod; (b) surface microstructure; (c) fracture surface, ex-  can alter the response of dosimeters to differ-
               hibiting cleavage planes in transgranular fracture.
                                                              ent radiation types, so this fact should be con-
                                                              sidered in clinical dosimetry. The TL response
               External Dosimetry                             of LiF:Mg,Ti microdosimeters and CaSO :Dy
                                                                                                      4
                                                              dosimeters were studied for 12 MeV electron
               Dosimetry in computerized tomography           beams using PMMA, liquid water and solid
               and evaluation of the dose profile             water (SW) phantoms. The dosimeters were

                                                              irradiated with doses ranging from 0.1 up to
               A new method for determination of absorbed     5 Gy using a Varian Clinac  0C linear acceler-
                                                                                       210
                                                                                     2
               doses in computed tomography examinations      ator using a 10 x 10 cm  field size and 100 cm
               was developed using the Fricke gel solution    source-phantom surface distance, with the do-
               developed at IPEN. Absorbed doses were de-     simeters positioned at the depth of maximum
               termined by different methods of analysis:     dose. CaSO :Dy dosimeters produced at IPEN
                                                                         4
               optical absorption spectrometry – O.A., mag-   presented higher TL sensitivity and intrinsic
               netic resonance imaging - MRI and ionization   efficiency than microLiF:Mg,Ti from Thermo