Page 28 - Personal Study Notes (Engineering Metrology - 22342)
P. 28

Page 28 of 176





               3. Different gauging heads are needed for different jobs.

               4. Auxiliary equipments such as air filters, pressure gauges and regulators are needed.


               5. Non-uniformity of scale is a peculiar aspect of air gauging as the variation of back
               pressure is linear, over only a small range of the orifice size variation.

               Q. Why do we need magnification? and what is magnification?


               Magnification is nothing but multiply the small movement of the spindle/ Plunger/ Stylus
               to convert this movement on to a large scale, consisting a number of divisions( Example
               a dial).



































































                                                            Engineering Metrology (Only For Personal Use)  20
   23   24   25   26   27   28   29   30   31   32   33