Page 266 - Catalogue 2016 - 17
P. 266

FIRST AID - PARAMEDICAL - EMERGENCY


           i-PAD PUBLIC ACCESS DEFIBRILLATOR                                                      Information button

       The i-PAD NF 1200 is a semi-automatic external defibrillator designed for                                State LED
       minimally trained individuals. It provides simple and direct voice prompts
       and indications for a straightforward rescue operation. It is lightweight
       and battery powered for maximum portability. It is designed to treat Ventricular
       Fibrillation (VF) and Fast Ventricular Tachycardia. These two are the most common
       causes of sudden cardiac arrest (SCA). In SCA, the heart of the victim suddenly stops
       pumping. The only effective treatment for VF is the application of a defibrillating
       shock. It may be used on children 1-8 years old (less than 25 kg) with pediatric
       reduced energy pads, over with adult pads. Supplied with a set of adult
       pads, lithium battery (200 Shocks or 10 hours operating time), manual.
       According to ERC Guidelines 2010.                                                                         Battery
       TRAINER: simulates all the functions of i-PAD, with 8 rescue scenarios.                                   pack
                          i-PAD DEFIBRILLATOR AND TRAINER
        Voice version
         and manual   Spanish   French   Portuguese  Italian   English   Other
                                                      languages*                                            IrDA port used
       DEFIBRILLATOR   33408   33409   33413   33414   33416   33417  Pads                                  for data com-
                                                                 connector guide
         TRAINER      -     -       -    33424  33405  33406                   Shock                        munication
       * Voice languages: DE, DK, KR, JP, NL, SE, with same language manual, updated to ERC guidelines 2010  0470  button
       * Voice languages: CZ, GR, HU, IL, IR, NO, TR, with English manual, updated to ERC guidelines 2005  SPECIALLY DESIGNED
         GIMA code             Original accessories for I-PAD               JFDA                  FOR PUBLIC USAGE
             33418   Lithium battery pack
             33441   Disposable pads - kit of 2 pcs                                Size: 32.5x34x18 cm
             33443   Disposable pediatric pads - kit of 2 pcs
             33422   Carrying bag
             33423   Wall cabinet with alarm sound
             33403   IrDa connector for data communication + software
                   for event recording download with key file     33405             33423         33422
                                                     TECHNICAL SPECIFICATIONS
        Operating mode:    Semi-automatic                     Charge time from “Shock advised”:  < 10 seconds, typical
        Waveform:        e-cube biphasic (Truncated exponential type);  Voice instruction:    Voice messages guide through use of defibrillator
                         impedance compensated                Controls:         Shock Button, i-Button, On/Off Button
        Energy:          200J fixed                            Indicators:       7 LEDs ( different colors), i-Button
                         Adult: nominal 150 J into a 50 ohm load  Patient isolation:    Type BF, defibrillation protected
                         Infant/child: nominal 50 joules into a 50 ohm load  Battery:   12 Volt DC, 4.2 Ah, lithium manganese dioxide,
        Shock energy accuracy:    Within ±3% (200 J into 50 Ω)                  disposable long-life primary cell
        Shock to shock cycle time:  Typically less than 20 seconds  Battery capacity:    Min. 200 Shocks or 10 hours of operating time
        Protocol:        Voice prompts and indicators guide through protocol  Data recording:   Data Stored: First 40 minutes of ECG and the entire
        Charge control:   Automatic by Software (Arrhythmia Detection           incident’s events and analysis decision
                         System and Charging Control)         Size - Weight:    220x260x70 mm - 2.2 kg (4.84 lbs) with battery pack

           RESCUE SAM AED DEFIBRILLATOR

         5 YEARS WARRANTY                                    Rescue Sam is a semi automatic external defibrillator designed for
           MADE IN ITALY                                     public use by minimally trained people. It provides easy and simple
                                                             indications for rescue operations. Supplied with lithium battery
                                                             (200 shocks or 4 hours operating time), set of adult pads and
                                                             manual. According to AHA/ERC Guidelines 2010. Made in Italy.
                                                               GIMA             RESCUE SAM DEFIBRILLATOR
                                                                code
                                                               33425  Rescue Sam defibrillator - English
                                                               33426  Rescue Sam defibrillator - Italian
                                                               33427  Rescue Sam defibrillator - French       33421
                                                               33430  Rescue Sam defibrillator - Spanish
                                                               33559  Rescue Sam defibrillator - other languages *
                                                              * Other languages available in 20 days: DE, PL, NL, CZ, SE, TR, FI, RU
                                                               33419  Lithium battery pack
                                                               33458  Disposable pediatric pads (kit of 2)
                                                               33448  Disposable adult pads (kit of 2)
                                                               33420  Disposable adult pads (kit of 2) and cable
                                                               33421  Carrying bag
                                                                              TECHNICAL SPECIFICATIONS
                                                               Operating mode:      Semi-automatic (DAE)
                                                               Waveform:            BTE (Biphasic Exponential Truncated)
                                                                                    impedance compensated
                                                               Energy:              200 J fixed
                                                               Charge control:      Automatic by software (Arrhythmia Detection
            0068                           33425                                    System and charging control)
                                                               Charge time:         < 8 seconds
                                                               Time between discharges:   < 20 seconds
                                                               ECG data acquisition:   Derivation II, by defibrillation pads.
                                33419                                               Band from 1 Hz to 35 Hz
                                                               Impedance:           25 Ω to 200 Ω
                                                               ECG analisis system:
                                                     33420     Voice instructions:   Vocal and optical message guide
                                                               Autotest:            automatic, battery insertion,
                                                                                    daily/weekly/monthly
                                                               Long life battery:   12 Volt DC, 42 Ah, LiMnO  disposable
                                                                                                     2
                                                               Battery capacity:    200 shocks or 4 hours of operating time
                                                               Data recording, stored:   first 60 minutes of ECG and the entire
                                   Disposable adult                                 incident's event
                                   pads with cable             Size-weight:         30x28x9 h cm - 2.3 kg with battery
       257