NATCEM AC





            Method of use                                                      Application



            Preparing the surface             Priming                          General                                             Setting times                     Storage                          How to specify
            Do not use on frozen or           There is no need to prime any    Place the material as quickly                       NATCEM AC is designed to          NATCEM AC is packaged in a       NATCEM AC shall be mixed and
            overheated substrates (Outside    reinforcement, but if priming    as possible after mixing using                      commence setting at 35 minutes    polythene inner bag with         applied to prepared surfaces all
            the range of 0˚c-30˚c). Prepare the   is preferred, any conventional   traditional tools. A 3mm minimum                and finish setting at 40 minutes at   re-sealable tie in a stitch sealed   strictly in accordance with the
            surface in advance to provide an   system may be used.             thickness of the material is                        20˚c. In winter NATCEM AC can     woven polypropylene outer bag    manufacturer’s instructions.
            adequate key. It should be clean,   On reinforcement it is only    always necessary. DO NOT apply                      be used down to 0˚c. The set will   that should be stored in dry
            free from dust and thoroughly     necessary to remove the loose    additional water to the surface                     be slower but can be accelerated   conditions and will remain usable   Precautions
            dampened. Where necessary         rust, which can be done by wire  during finishing as this may cause                   by using warm water. In very hot   for at least twelve months.     We strongly recommend the
            steel or aluminium mesh can       brushing.                        surface cracking. Once setting                      temperatures the set will be faster                                use of GLOVES, GOGGLES and
            be used. Ensure that a 3mm                                         has started DO NOT attempt to                       and can be slowed by using cold   Yield                            MASK. Please see SDS sheet
            minimum thickness of material is                                   remix or to smooth the surface,                     water.                            Generally 1 x 25kg bag of        for full details.
            obtained.                                                          this will cause the mechanical                                                        NATCEM AC mixed with 5 litres of
                                                                               properties in particular strength                   Cleaning                          water will produce approximately   Approved to Reg 31 for
                                                                               and adhesion to be lost.                            NATCEM AC should be removed       10 litres of finish mortar.       use in  public water
                                                                                                                                   from tools and equipment and                                       supplies. Secretary of
            Mixing                                                                                                                 cleaned with water immediately    Disposal of Waste                state for D.E.T.R.
            APPLICATION BY TROWEL                                                                                                  after use.                        Via an authorised waste disposal  Approved.
            If one bag or less is to be mixed it should be mixed with a rose bud type paddle attached to an electric drill                                           contractor to an approved waste  6th May 2015
            (900 rpm, 1000 W). Mix vigorously for at least 2 minutes after adding all the mixture to the water. NATCEM AC                                            disposal site, observing all local  DWI 56.4.840
            is designed to give a fluid mix but this only develops after sufficient mixing. For larger quantities, optimum mix                                       and national regulations.
            results can be obtained using conventional mixing machines. When applying by plastering methods, add the
            NATCEM AC gradually to 5 litres of clean water per bag, whilst mixing continuously. The mix will appear dry            Setting time & strength gain
            at first. Continue mixing until fluidity develops. If greater fluidity is required additional water may be added to a
            total of 5.5 litres per bag. Exceeding this ratio will lead to lower strength and a longer setting time. In cold weather      Start Set             35 Min               at 20°c
            the set can be accelerated using warm water, likewise in hot weather cold water can be used to slow down the                  End Set               40 Min               at 20°c
            set.
                                                                                                                                                                                   Compressive
            APPLICATION BY BRUSH OR ROLLER                                                                                                                                        Strength (Mpa)
            If one bag or less is to be mixed it should be mixed with a rose bud type paddle attached to an electric drill
            (900 rpm, 1000 W). Mix vigorously for at least 2 minutes after adding all the mixture to the water. NATCEM AC                  1 Hour                                       4
            is designed to give a fluid mix but this only develops after sufficient mixing. For larger quantities, optimum mix            3 Hours                                       5
            results can be obtained using conventional mixing machines. When applying by brush or roller methods, add                     24 Hours                                      9
            the NATCEM AC gradually to 6 litres of clean water per bag, whilst mixing continuously. The mix will appear                    7 Days                                      13
            dry at first. Continue mixing until fluidity develops. If greater fluidity is required additional water may be added          28 Days                                      32
            to a total of 6.5 litres per bag. Exceeding this ratio will lead to lower strength and a longer setting time. In cold
            weather the set can be accelerated using warm water, likewise in hot weather, cold water can be used to slow                          Strength continues to develop thereafter.
            down the set. When applying by brush or roller, two coats may be necessary to ensure no pinholes and
            adequate 3 mm minimum thickness. Ensure that the first coat has set prior to application of the second coat
            and that the surface of the first coat is well wetted prior to the application of the second coat.









    2 of 4.                                                                                                                                                                                                                          3 of 4.
   29   30   31   32   33   34   35   36   37   38   39