Page 682 - Fluid, Electrolyte, and Acid-Base Disorders in Small Animal Practice
P. 682

Peritoneal Dialysis   669


            PROTOCOL FOR                                        and subcutaneous layers become anchored by ingrowth
                                                                            6,64
            PERITONEAL DIALYSIS                                 of fibroblasts.  The fluted aspect of the catheter is
                                                                placed against the parietal peritoneum and oriented in a
                                                                cranial to caudal plane. The catheter is flexible and
            CATHETER TYPES AND PLACEMENT                        designed to temporarily fold at the crosspiece to facilitate
            The key to successful PD is the catheter and its placement.  insertion. The fluted aspect of the catheter is 30 cm in
            An ideal catheter allows efficient inflow and outflow, is
            biocompatible, resists infection of both the peritoneum  BOX 28-3     Suppliers of Peritoneal
            and subcutaneous tunnel, and retards leakage at the peri-             Dialysis Catheters
            toneal exit site. 18  One of the most common causes of
            catheter failure in small animals is catheter obstruction
            by omentum, resulting in failure to drain dialysate from  Medigroup, Inc.
            the abdomen. There are many catheter designs available  505 Weston Ridge Drive
            (Box 28-3), and most are modifications of a fenestrated  Naperville, IL 60563-3932
                                                                   800-323-5389
            silicone tube with Dacron (Invista, Wichita, Kan.) cuffs
                                                                   630-428-4148 (fax)
            applied to promote fibrous attachments at the peritoneal
                                                                   www.medigroupinc.com
            and cutaneous exit sites (Figure 28-3). Simple tube
                                                                   Ash Advantage Peritoneal Catheter
            catheters with stylets can be placed percutaneously in  Adult, standard
            conscious animals using local anesthetics in an emergency  Flex-Neck Peritoneal Catheter
            situation. 23,24,53  A percutaneous cystotomy tube catheter  Coiled Adult Standard and Large
            (Stamey percutaneous suprapubic catheter set, Cook,    Kendall Healthcare/Kendall Vascular
            Spencer, Ind.) also has been used successfully for acute  15 Hampshire Street
            short-term PD (Figure 28-4). The Tenckhoff catheter,   Mansfield, MA 02048
            developed in 1968, is a straight soft Silastic tube    800-962-9888
                                                                   www.kendallhq.com
            fenestrated at the distal end and furnished with two
            Dacron velour cuffs. 65  Because of the high rate of omen-  A variety of peritoneal dialysis catheters
                                                                   Medcomp
            tal entrapment, surgical omentectomies are advocated
                                                                   1499 Delp Drive
            when using this catheter in animals in which more than  Harleyville, PA 19438
            3 days of dialysis is anticipated. 12,23,24  PD for acute renal  215-256-4201
            failure should be performed for a minimum of 48 to 72  www.medcompnet.com
            hours, but the animal’s condition often necessitates a lon-  Straight and curled, one and two cuff peritoneal dialysis
            ger period of treatment.                                 catheters
              An alternative catheter style called the fluted-T (Ash  Cook Surgical
            Advantage peritoneal dialysis catheter, Medigroup,     P.O. Box 489
            Aurora, Ill.) has produced good results in dogs        750 Daniels Way
            (Figure 28-5). In one study, 17 dogs had fluted-T      Bloomington, IN 47402-0489
            catheters placed by peritoneoscope and were dialyzed   812-339-2235
                                                                   800-457-4500
            daily. Only four catheters had outflow failure that
                                                                   www.cooksurgical.com
            occurred 7 to 18 days after placement. The remaining
                                                                   Acute and chronic peritoneal dialysis catheters, Tenckhoff
            catheters functioned for the entire study period of 60   and Spiral
            days. 6,64  In the same study, Tenckhoff catheters in the  Global Veterinary Products, Inc.
            dogs were obstructed by omentum 2 to 4 days after      19601 West U.S. Highway 12
            placement.                                             New Buffalo, MI 49117
              The flutes are designed to offer minimal resistance to  269-469-8882
            influx and efflux of fluid while preventing omental adhe-  269-469-9940 (fax)
            sion. The design of this catheter prevents outward migra-  www.globalvetproducts.com
                                                                   Acute peritoneal dialysis catheter, coaxial design
            tion. There is diminished hydraulic resistance during
                                                                   Cook Urological Incorporated
            inflow and outflow because most of the dialysate flow
                                                                   1100 West Morgan Street
            pathways are around the catheter rather than within it.
                                                                   P.O. Box 227
            There is more complete drainage of the peritoneum
                                                                   Spencer, IN 47460
            through the limbs of the catheter, which are directed both  812-829-4891
            cranially and caudally in the abdomen. Any residual    800-457-4448
            omentum appears to have more difficulty attaching to   812-829-2022 (fax)
            the slots in the catheter than to the small holes in more  www.cookurological.com
            traditional catheters. This silicone catheter has two  Stamey percutaneous suprapubic catheter
            Dacron cuffs that when implanted in the rectus muscle
   677   678   679   680   681   682   683   684   685   686   687