Page 2390 - Cote clinical veterinary advisor dogs and cats 4th
P. 2390

Vaginal Cytology   1183


           •  The collection bag should be emptied based   chlorhexidine  solution.  Flush  the  vulva/  temporarily clamping the line during animal
                                                prepuce with 0.05% chlorhexidine solution.
             on a predetermined schedule (e.g., q 1-8h)   •  Empty closed collection system (if needed).  transport can prevent retrograde flow of urine
                                                                                    back into the animal.
             or when it is almost full.
  VetBooks.ir  •  Wash hands before and after handling the   •  The urine collection line and bag should be   •  When moving a patient with an indwelling
                                                                                    urinary catheter, ensure that the collection
             urinary catheter or collection system.
                                                replaced when there is gross contamination
           •  Put  on  exam  gloves.  Evaluate  the  urinary
                                                                                    retrograde flow of urine back to the animal.
             catheter and collection system, and ensure   that cannot be easily cleaned.  bag is always below the patient to prevent
             that the catheter is still in place and there   Postprocedure
             are no leaks in the system.       Ensure that all disconnected bags or lines   SUGGESTED READING
           •  Use surgical scrub to clean skin around the   are properly connected after collection bag is   Aldrich J: Urethral catheterization. In Creedon JM,
             vulva/prepuce,  as  well  as  exposed  area  of   emptied.            et al, editors: Advanced monitoring and procedures
             the catheter and collection system. Follow                            for small animal emergency and critical care, ed
             by rinsing with gauze and water.  Pearls                              1, West Sussex, UK, 2012, John Wiley & Sons.
           •  Wipe  the  skin  around  the  vulva/prepuce,   •  Clamps attached to fluid lines are usually   AUTHOR: Adesola Odunayo, DVM, MS, DACVECC
             as well as exposed area of the catheter and   removed to prevent them from being acciden-  EDITORS: Leah A. Cohn, DVM, PhD, DACVIM; Mark S.
             collection  system  with  gauze  and  0.05%   tally closed, preventing urine flow. However,   Thompson, DVM, DABVP  Procedures and  Procedures and   Techniques  Techniques






            Vaginal Cytology                                                                         Bonus Material
                                                                                                          Online


           Difficulty level: ♦                 •  A  fast  Romanowsky-type  stain  kit  (e.g.,   Procedure
                                                Diff-Quik)                        •  Wet the cotton-tipped swab with a couple
           Synonym                             •  A booklet of bibulous paper       of drops of saline solution.
           Colpocytology                       •  A brightfield microscope        •  Introduce the swab just ventral to the dorsal
                                                                                    vulvar commissure into the vaginal vault.
           Overview and Goal                   Anticipated Time                   •  Advance the swab 0.5-3 cm (depending on
           Examination of cells exfoliated from the   Total procedure: < 10 minutes  dog breed and size) horizontally into the
           vaginal epithelium can assist in determining   •  Sample collection: 10-60 seconds  vestibular area, and then immediately tip it
           reproductive  status  and  local  inflammatory   •  Making  of  slide  smear  and  staining:  ≤ 4   at ≥ 45° angle (almost toward to the anus)
           conditions (vaginitis). In clinical practice, it   minutes               and advance it craniodorsally until in the
           is important to determine whether the bitch   •  Reading  of  slide  and  interpretation:  ≤ 2     vagina proper.
           has a keratinizing (proestrus) or keratinized   minutes                •  The swab is then repositioned horizontally,
           vaginal epithelium (estrus).                                             and adequate exfoliation of vaginal epithe-
                                               Preparation: Important               lium cells can be accomplished by moving
           Indications                         Checkpoints                          the swab tip back and forth and by twirling
           •  Staging  the  bitch’s  reproductive  status  for   •  Have a kit with main supplies for collecting   the swab shaft a couple of times.
             breeding management                the vaginal specimen: a box of glass slides,   •  The swab is then quickly withdrawn from
           •  Assisting  in  determining  whether  a  previ-  a 3-mL syringe that has been prefilled with   the bitch’s vagina and rolled onto the glass
             ously spayed bitch  is experiencing  estrual   saline solution, a permanent marker or   smear in two or three streaks; do not roll
             symptoms resulting from ovarian remnant   pencil to write the patient’s ID in the glass    the swab tip back and forth on the same
             syndrome (p. 732) or exposure to exogenous   slide                     area.
             hormone. Vaginal keratinization (cornifica-  •  Ensure  a  stain  kit  and  a  microscope  are   •  Air-dry and proceed to staining (according
             tion) is a bioassay for estrogen.  available for use.                  to the manufacturer’s instructions).
           •  Evaluating the nature of any vulvar discharge                       •  Blot the wet, stained slide onto a sheet of
                                               Possible Complications and           bibulous paper, and proceed to brightfield
           Contraindications                   Common Errors to Avoid               microscopy.
           None; care and strict aseptic technique must   •  Avoid  inadvertently  introducing  the  swab   •  Initial screening of the slide is done at 100×
           be used when sampling the pregnant bitch.  into the bitch’s urethra. When that happens,   magnification for an overall assessment of
                                                a  diagnosis  of  nonkeratinized  (cornified)   types of cells (i.e., determination of the
           Equipment, Anesthesia                vaginal smear is made. To avoid it, ensure   percentage of cornified vs. noncornified
           •  Cotton-  or  rayon-tipped  swab,  prefer-  the  swab  is  introduced  into  the  bitch’s   vaginal epithelial cells).
             ably  with a (semiflexible)  plastic  shaft   vagina just ventral to the dorsal vulvar     •  Intermediate  stages  of  epithelial  cells  or
             (polystyrene) that is 6 inches long. Sudden   commissure.              microorganisms  (fungal,  bacterial)  can  be
             movements by uncooperative bitches may   •  For vaginal smears without enough cells for   further examined at 400× or 1000× (under
             cause the wooden-shaft, cotton-tipped swabs   interpretation, repeat the procedure to ensure   immersion oil) if needed.
             to break during the specimen collection     enough cells are collected.  •  Noncornified  cells  (parabasal  and  small,
             procedure.                        •  Vaginal smears with too many spindle-shaped   intermediate-stage cells) are small, round cells
           •  A 3-mL syringe with saline solution to wet   cells likely indicate that vestibular or clitoral   with a large, stippled nucleus. Noncornified
             the cotton tip                     fossa cells, not vaginal epithelial cells, were   cells have large nucleus-to-cytoplasm ratios.
           •  A  glass  slide  (preferably  a  premium  pre-  collected. For proper reading and interpreta-  Cornified cells (large, intermediate-stage and
             cleaned glass slide with frosted end for patient   tion, cells must be collected from the middle   superficial cells) have a more angular shape,
             identification)                    to cranial vaginal regions.         and the nucleus is pyknotic or not apparent

                                                      www .ExpertConsult.com
                                                      www.ExpertConsult.com
   2385   2386   2387   2388   2389   2390   2391   2392   2393   2394   2395