Page 103 - A Practical Guide to Equine Radiography
P. 103

84  A PRACTICAL GUIDE TO EQUINE RADIOGRAPHY



                   Dorso 35º proximal-dorsodistal                  4.  Position the X-ray machine on the cranial
      VetBooks.ir  oblique (D35Pr-DDiO) or ‘skyline’               5.  Focus–film distance: 100 cm.
                                                                      side of the limb above the carpal region.
                   view of the distal row of carpal bones
                   (Figs 8.29–8.32)                                6.  Angle the X-ray beam 35 degrees downward
                   1.  Flex the carpus with gloved hands so that      towards the horizontal.
                       the metacarpus is horizontal.               7.  Centre the X-ray beam at the level of the dor-
                   2.  Place the plate in a horizontal position       sal border of the distal row of carpal bones.
                       facing upwards under the metacarpus,        8.  Collimate around the dorsal half of the
                       extending beyond its dorsal border.            distal radius.
                   3.  Place a R/L marker on the lateral side of the   9.  Exposure guide: 65 kVp, 8 mAs.
                       plate.




                   A                                                        B



























                   Figure 8.29  Diagram showing how to obtain D35Pr-DDiO view of the carpus (A) and positioning to obtain 
                   the same view (B).








































       Equine Radiography-01-cnewlayout.indd   84                                                                27/11/2018   11:33