Page 218 - A Practical Guide to Equine Radiography
P. 218

THORAX  199



                  Laterolateral (LL) in lateral recumbency        4.  Position the X-ray machine above the foal.
      VetBooks.ir  in foals (Figs 17.13–17.15)                    5.  Focus–film distance: 120 cm. If a grid is

                                                                     used, adjust the focus–film distance to the
                  1.  Position the foal in lateral recumbency on
                      a padded surface, keeping the neck paral-      distance specified for the grid.
                      lel to the ground by supporting it and both   6.  Use a vertical X-ray beam.
                      forelimbs extended forward with gloved      7.  Centre the X-ray beam in the middle third
                                                                             th
                      hands.                                         of the 8  intercostal space.
                  2.  Place the plate under the thorax, in land-  8.  Collimate to the edge of the plate.
                      scape orientation; a tunnel block will      9.  Exposure guide: 75 kVp, 30 mAs.
                      facilitate this.
                  3.  Indicate  right/left  (plate’s  side)  with  a
                      marker.







































                  Figure 17.13  Positioning to obtain a LL view of the thorax in lateral recumbency in foals.

































       Equine Radiography.indb   199                                                                             27/11/2018   11:15