Page 220 - A Practical Guide to Equine Radiography
P. 220

THORAX  201



                  Ventrodorsal (VD) in foals                      3.  Indicate right/left with a marker.
      VetBooks.ir  (Figs 17.16–17.18)                             4.  Position the X-ray machine above the foal.

                                                                  5.  Focus–film distance: 120 cm. If a grid is
                  1.  Position the foal in dorsal recumbency
                      without rotation onto a padded surface,        used, adjust the focus–film distance to the
                      keeping the neck and both forelimbs            distance specified for the grid.
                      extended forward and the hind limbs in      6.  Use a vertical X-ray beam.
                      a frog-leg position. Personnel involved in   7.  Centre the X-ray beam in the midline just
                      foal restraint must wear lead gloves.          caudal to the xiphoid process.
                  2.  Place the plate under the thorax, in portrait   8.  Collimate to the edge of the plate.
                      orientation along the long axis of the spine;   9.  Exposure guide: 90 kVp, 40 mAs.
                      a tunnel block will facilitate this.
































                  Figure 17.16  Positioning to obtain a VD view of the thorax in foals.










































       Equine Radiography.indb   201                                                                             27/11/2018   11:15
   215   216   217   218   219   220   221   222   223   224   225