50  A PRACTICAL GUIDE TO EQUINE RADIOGRAPHY



                   Dorsoproximal-dorsodistal oblique               4.  Position the X-ray machine dorsal to the
      VetBooks.ir  (DPr-DDiO) (Figs 6.17–6.20)                     5.  Focus–film distance: 100 cm.
                                                                      limb and proximal to the fetlock.
                   1.  Flex the fetlock joint with gloved hand and
                       keep the metacarpus vertical to the ground.  6.  Angle the X-ray beam 45–70 degrees down-
                   2.  Place the plate distal to the joint, parallel to   ward from the horizontal.
                       the ground and facing upwards, as close as   7.  Centre the X-ray beam at the level of the
                       possible to the limb.                          dorsal aspect of the fetlock joint.
                   3.  Place a R/L marker on the lateral side of the   8.  Collimate around the fetlock joint.
                       plate.                                      9.  Exposure guide: 60 kVp, 8 mAs.

























































                   Figure 6.17  Positioning to obtain a DPr-DDiO view of the fetlock.