and also stop overheating, which could cause a fire. Sometimes though
                   there were lightning strike on an equipment, you will be surprised that
                   only fuse were damaged and not the power supply section or components.

                                               There are two basic types of fuses which is the
                                               fast acting and slow blow type. The fast acting
                                               fuse will open very quickly when their particular
                                               current rating is exceeded. This is very
                                               important for analogue multimeter, which can
                   quickly be destroyed when too much current flows through them, for
                   even a very small amount of time.
                   Even if you are an experienced repairer, sometimes we do made mistake
                   by accidentally touching the probe to the testing points where it should
                   not be touch! The slow blow fuse has a coiled construction inside the
                   glass. Slow blow fuses are designed to open only on a continued
                   overload, such as a short circuit. The function of the coiled construction is
                   to stop the fuse from blowing on just a temporary current surge.

                   Don’t replace a slow blow fuse in place of a fast acting fuse because it
                   may not open fast enough to prevent components damage under a high
                   current condition. It’s not dangerous to substitute a slow blow fuse with a
                   fast-acting fuse, but it will probably open up unnecessarily every now and
                   then when the equipment is first switch on such as when you switch on a
                   Computer Monitor.























                            A blown fuse can indicate how severe the short circuit is.

                   There’s a secret for you, a blown fuse can indicate something about the
                   problem. If the glass case of the fuse appears clear or transparent, and if
                   you can still see the slight broken pieces of the fuse element, this means
                   that there’s no major short circuit in the circuit. Replacing the fuse with