4.3 Alternate Reject Option—continued
Configuring the Alternate Reject
To enable the Alternate Reject option in the software, follow these steps:
1. From the Main Menu, press the MENU key once to navigate to the Reject Menu.
2. Press S3 to enter Reject Setup.
Alt-Reject Setup
Del: 0.00 Dur:0.00
3. Press the UP Arrow key twice to find the Alternate Reject Menu.
4. Once you adjust either the Delay or Duration to a number above the default setting of zero, the system will
automatically enable the Alternate Reject as an independent reject output.
4.4 Date and Time Change
To edit the date and time:
1. At the Main Menu press “Select Unit”; then the DOWN (‐) arrow key to get to the Date and Time menu.
2. Press S2, a flashing cursor will appear; use the LEFT/RIGHT arrow keys to scroll the cursor between the
characters and UP/DOWN (+/‐) keys to change the characters.
3. Once the date and time are updated, press ENTER to confirm and EXIT.
NOTE: Do Not Forget to change the time when Daylight Saving Time begins or ends
4.5 IP Address
Detector is shipped with Default address of 192.168.1.51, if connecting to a network consult CONTACT Software
manual.
To change the IP address:
1. At the Main Menu press the SELECT UNIT button.
2. Press the UP/DOWN Arrow Keys until you see IP address
IP: 192.168.1.51
M: f8-99-55-c7-71-5c
3. Press S3 to change the IP address.