         4.5  IP Address—continued

            4.  A flashing cursor will appear on the first letter; press the UP/DOWN arrow keys (+/‐) to change the numeric
                characters. The LEFT/RIGHT arrow keys are used to scroll the cursor between characters.
            5.  Press Enter to confirm.

         4.6  Naming the Detector


         This name will be visible in CONTACT Reporter Lite software to identify then Detector. The name of the Metal Detector
         can be made more suitable or descriptive to production, line or plant.
         Follow these steps:

            1.  At the Main Menu press the SELECT UNIT button.
            2.  Press the UP/DOWN Arrow Keys until you see Detector’s Name.





                                                       DETECTOR NAME:
                                                         DETECTOR001



            3.  Press one of the lower Soft Keys (S2 or S4) alongside the Detector’s name to edit the name.

            4.  A flashing cursor will appear on the first letter; press the UP/DOWN arrow keys (+/‐) to change the
                alphanumeric characters. The LEFT/RIGHT arrow keys are used to scroll the cursor between characters.
            5.  Press Enter to confirm.


         4.7  FM Detect Mode

         FM detection mode analyzes the detection signal and uses an algorithm to calculate the signal strength based on a
         function of time and amplitude. This can significantly improve performance in certain applications. FM detect mode
         adds a slight delay to the detection process which may be critical in a gravity / high speed application.
         To use FM mode the detector needs to have information about the application (speed and detector size) to define the
         signal spectrum.  To set these two parameters follow these steps:

            1.  From the Main Menu, press the MENU key once to navigate to the Reject Men.
            2.  Press S3 to enter Reject Setup.

            3.  Press the DOWN Arrow (‐), then S4 to enter Setup.
            4.  Press S2 to enter the calculated or measured belt speed (median if the application is variable), then UP/DOWN
                (+/‐) to go through the options till you see DETECTOR DEPTH & WIN.



                                                        Detector       (in)


                                                Dept: 12.0             Win:    3.9