Gravity Metal Detector System—Operator Setup Manual
5.2 Faults
Fault Possible Cause Corrective Action
24V Power supply not functioning properly Power supply needs to be checked and/ or
replaced.
Air Pressure The air pressure sensor connected to the Verify air pressure going to the sensor with the
isolated input of the DSP board (PL10 pins reject device set to factory default; typically about
9 & 10) is indicating a low pressure which 60‐80 P.S.I.
may impair the proper function of the re‐
ject device. Verify air pressure sensors are installed.
Verify air pressure proper functionality.
Air pressure sensor not functioning prop‐
erly . Faults can be cleared and masked in the software,
until a technician has verified and corrected the
causes of the fault
Balance There is metal located within the Detector Verify that no metal is located within the Detector
aperture. aperture.
The Detector balance is excessive. Check if LD3 (yellow LED) on DSP board is on.
Date Time Indicates the time is not set. Set the correct date and time.
Excess The number of rejects has exceeded the Check rejected product for metal contaminants.
Reject limit set within the software Feature is Make sure the Detector is calibrated for the
enabled via Fault Setup Menu.
running product
Can be cleared via the Clear soft key (S3)