Gravity Metal Detector System—Operator Setup Manual
5.2 Faults—continued
Fault Possible Cause Corrective Action
Internal USB There is an issue with the internal USB Contact Fortress Service Dept.
storage. 1‐888‐220‐8737 or 416‐754‐2898
Large Metal The large metal threshold limit has been Verify that no metal is located within the Detector
exceeded. aperture.
The large metal threshold has been set too Increase the large metal threshold.
low Feature is enabled within Sensitivity
submenu. Can be cleared via the Clear Soft key (S3) and
masked in the software’s Fault Menu
Low Battery This fault will be generated when battery Replace with a CR2032 battery.
PL20 is low.
Peye Block Photo Eye function is turned on. Check reject settings, reject setup should
be normal.
Turn photo reject off.
Phase Limit A phase limit was exceeded during a Can be cleared via the Clear soft key (S3).
calibration or auto phase update.
Check the phase point and perform a fast phase
calibration.
PROD Product memory may be corrupted Cycle power to clear memory or reset the product
Memory record via Reset in the Product, Edit Menu
Rej Bin Full The reject bin is full (this may prevent Check the bin and empty rejected product – handle
product from being successfully rejected according to operational procedures
into the bin)
Check that the sensor in the bin is not misaligned
Check the polarity of the input
Reject Reject confirmation device(s) failed to Check that the reject device is functioning properly
verify that the contaminated product was and that the confirmation devices are positioned
properly rejected correctly
Check if the polarity setting and the time delay
within the software is set
Reference DSP PL1 Wire not connected properly Check if DSP PL1 board interconnection cable/plug
are fully located with no loose connections
SH Board circuitry may be faulty
Call Fortress for assistance to check if SH Board is
faulty
Test Signal Test signal was not detected during a test Check the sensitivity and perform a manual test
procedure
Call Fortress for assistance to check if SH Board is
faulty
www.fortresstechnology.com Page 47