Page 12 - portfolio
P. 12
i
d
b
h
h
Elevation "B"
100 Detail "J6" Elevation "F" D4 h Detail "J4" Elevation "A" n b W19
100
Elevation "G"
1500 400 400 400
50 50 50 50 Elevation "H" n a p h
Refer sheet no AB-DLF-ID-139
for the cladding details for this wall
Elevation "C"
Elevation "I"
Elevation "D"
1335 D4 650 530
1195
360 565 965 720 720
600 1125
Elevation "J"
720
655
1735
875
550
645 680
850 1380
1335 D4 530 370 690
Elevation "E"
n
a
a
a
a
Detail "J4"
i
n
h
a
b
d
c
p
900 200 900 [3'-6"] 1065 Detail "J4" Detail "J10"
750 [3'-6"] 500 1065 1065 [1'-7"] 475
[5'-3"] 1600 [9"] 215
100mm skirting
1600
[1'-1"] 340
glass) 300x300mm
1250 [4'-1"]
(junction details )
[4'-3"] 1305
level difference of 5mm
2400
[7'-10"]
[2'-3"] 695
mm veneer as per details
[3'-5"]
1035
[2'-4"]
700
be applied on in two layers.
FINISHES LEGEND
External window as per DLF
3050
Wall finish in P.O.P and paint
1060 [3'-6"] 900
565 [5'-9"] 1750
key plan
[3'-2"] 970 900 [4'-6"] 1365 1700 [5'-7"] 1990 200
[3'] 915
4260 [14']
90 [3"]
(0.07 Kg/Sft) shall be firmly stretched and
x 1/8" and s.s dash fasteners including all
125 3165 [10'-5"] [5"] [9"] 235
¾” x 24g) shall be at 15” c/c . The main G.I.
[1'-3"] 375
Metal strips 25 mm wide inserted on a
screwed to the intermediate frame with G.I.
5000 [16'-5"] 1230 [1'-5"] 435 [19'-6"] 5955
Refer sheet no AB-DLF-ID-138
12 mm BWP is fixed on 25x25 mm aluminium
adhesive, on a grid of aluminum channels. In
member to be hanged with help of G.I angle
panel of aluminium frame, ply & veneer.
10mm Bronze Metal Strips to be inserted with a
between the stone and wooden veneer a 10 x
ply board for the support of the blind/curtains/
Providing and fixing in position Wooden veneer
Pelmets (Wooden structure with use of wooden
washers and average 20 mm plaster of paris to
wiremesh as per detail in all RCP,Elevations and
be at 2’6” c/c and intermediate frame ( 21/2” x
and stone paneling cladded on 12mm PLY with
over G.I. metal frame work of appd. quality and
necessary work required. Expanded metal mesh
of 1" x 1" x 24 gaugeand additional M.S flats 3/4"
battens in a grid of 600x600 and finished with 4
Providng and fixing in position appd veneer
AB-DLF-ID-107 to AB-DLF-ID-109
Providing and fixing in position P.O.P. false ceiling
675
FOR DETAIL J1-J9:Refer sheet no
[2'-3"]
Sections. The main G.I. frame ( 24gx 2” x 1”) shall
1080 [3'-6"] [12'-11"] 3925
for the Detail marked as J1 to J9
[10'] 3060 [5'-9"] 1750
n
i
a
a
for the cladding details for this wall
Detail "J6"
CLIENT DRAWN BY: JIVITESH NOTES DRAWING TITLE DRAWING NO. :
CHECKED BY: 1. This drawing is the property and copyright of THE DESIGNER and shall not be copied or used in any way without their written permission.
Mrs. & Mr. 2. All dimensions are in mm and to be read only and not measured. Bedroom-1 AB-DLF-ID-010
3. Project managers/contractors to verify all site conditions and any condition different or not in correlation with the drawings/details must be immediately informed to
Date: 26.08.19
the architects.
Bhutani Scale 1:50 4. The information in the dwg is to be taken in conjunction with the specification documents and other documents that constitute the contract documents in their REVISION INTERIOR DESIGNERS
entirety.
5. It shall be deemed the responsibility of the contractor or the fabricator to bring to the notice of the DESIGNER prior to any construction or fabrication any NO. DATE PARTICULARS
PROJECT discrepancy within or between the aforementioned drawings. The designers have described their intentions and designs, to the best of their ability and knowledge,
in the contract documents.
2. Contractor should submit the shop drawings/ assembly detailed drawings for approval to the architect and client representative.
NE E 3. Contractor should submit all the material samples for consultant's approval prior to start of material procurement and start of work.
INTERIORS FOR N SE 4. Contractor must erect a sample of partitions ,wooden ceilings ,floorings,wall claddings ,fixtures and fittings etc. prior to commencing remainder of the work.
S perfect setting
NW 5. Contractor ,sub contractor and /or supplier remains responsible for all aspects of safety and security of the product supplied by them as well as drawings
RESIDENCE AT 820-B W SW submitted for checking.
6. Architect will only be responsible for approving design intent of shop drawings .No responsibility will be taken by the architect for structural/electrical/plumbing
CAMELLIAS HVAC or general safety of the final product.
7. PMC should co-ordinate with contractor/ vendors for timely submission of all above points.