Page 21 - 2018 ILP Catalog
P. 21
Sealing Mats & Films Innovative
Laboratory
Products
PCMATR-9-PRT PCSEPTA-9-N
PCMATR-3-PRT PCSEPTA-16-N
storage &
PCMATR-9-N PCSEPTA-B-N collection plates
separation
Silicone mats, for storage, assay, and separation plates Silicone mats, for PCR plates plates
Half height 8-channel and 12-channel reservoirs assay
plates
Plate Printed Mat Coated Mat
reservoirs
DP12VS-9-N DPMATS-9-PRT DPMATS-9-N-CR
DP22VS-9-N DPMATS-9-PRT DPMATS-9-N-CR Designed for universal fit on all major PCR
DP10UR-9-N DPMATR-500-PRT DPMATR-65-N-CR brand PCR plates, our silicone mats are products
DP12UR-9-N DPMATR-9-PRT DPMATR-9-N-CR compression formed in a class 10,000 sealing
DP2MUR-9-N DPMATR-9-PRT DPMATR-9-N-CR clean room. They efficiently seal your mats & films
DP20UR-9-N DPMATR-9-PRT DPMATR-9-N-CR sample, preventing evaporation, while
leaving you the ability to access each di-
DP4MVS-4-N DPMATS-4-PRT DPMATS-4-CR rectly through the preslit mat tops.
DP5PYR-4-N DPMATS-4-PRT DPMATS-4-CR
DP12VS-3-N DPMATS-3-PRT DPMATS-3-N-CR PCR plates minimize sample evapo-
DP19VS-3-N DPMATS-3-PRT DPMATS-3-N-CR ration in thermal cycling and storage
DP08VR-9I-N DPMATR-500-PRT DPMATR-65-N-CR applications; especially for storage at
higher temperatures or for applications
DP13UR-9I-N n/a DPMATR-9I-N-CR
involving aggressive solvents. Mats are
DP16US-9-N DPMATS-9-PRT DPMATS-9-N-CR suitable for use during thermal cycling
DP21US-9-N DPMATS-9-PRT DPMATS-9-N-CR and as compression mats.
DP33VR-9-N DPMATR-9-PRT DPMATR-9-N-CR
Made of research-grade silicone, con-
DP36VR-9-N DPMATR-500-PRT DPMATR-65-N-CR
taining no adhesives or extractables to
DP35UR-9-N DPMATR-9-PRT DPMATR-9-N-CR
contaminate samples. All mats can be
DP04UR-9-N DPMATR-500-PRT DPMATR-65-N-CR autoclaved, and following a 10% bleach
Non-printed Mat wash and ethanol rinse protocol may be
PC20NS-9-N PCMATR-9-PRT PCMATR-9-N reused. Certified to be free of RNase,
DNase, and Pyrogen contamination.
PC20HS-9-N PCMATR-9-PRT PCMATR-9-N
PC10HS-9-W-LC PCMATR-9-PRT PCMATR-9-N
The reservoir SEPTA-9 (Mat), -12 (seg-
PC10FS-9-N PCMATR-9-PRT PCMATR-9-N ment), and -B (plug) are for use with
PC10ES-9-N-ABI PCMATR-9-PRT PCMATR-9-N ABI3100, 3130 Analyzer and ABI PRISM®
PC20ES-9-N-ABI PCMATR-9-PRT PCMATR-9-N 3100 AVANT® Genetic Analyzer
Silicone mats are autoclavable (121C at 15 psi/1 atm for 15 min. - do not dry cycle) and following a 10% bleach wash and 21
ethanol rinse protocol may be reused. Made from 100% medical grade silicone.
www.i-labpro.com