Page 186 - The ROV Manual - A User Guide for Remotely Operated Vehicles 2nd edition
P. 186
FIGURE 8.18
Main trunk cable with molded branches.
(Courtesy Ocean Innovations.) Y-molds because they are reconfigurable and easily serviced. They do, however, take up more
space than a Y-mold.
Field installable termination assembly
Unlike other termination assemblies, the field installable termination assembly (FITA) (Figure 8.20) can be assembled on site without the need for molding. The system joins two multi- conductor cables in a pressure-compensated oil-filled environment. FITA terminations can be per- formed by trained operators on board, making it possible to repair broken cables without lengthy down time from sending the materials back for onshore repair.
8.2 Definitions 175