Page 38 - Prosig Catalogue 2005
P. 38

SOFTWARE PRODUCTS
  MULTIPLANE BALANCE & ACOUSTIC ANALYSIS



        DATS Multiplane Balancing Software                    DATS Acoustic Analysis Suite
    Training & Support  Multi-plane Balancing                  • Sound Power
                                                               • 1/N Octave Filters
         • Dual Tacho Support for 4x4 Vehicles
         • Zero Imbalance
                                                               • Sound Intensity
         • Specified Imbalance
                                                               • Sound Level Meter
         • Split Weight Calculation
                                                               • Transmission Loss
        analyzes the baseline
                                                               • Two Microphone Impedance Tubes
                      and
        vibrations
        then the vibrations                                    • Room Acoustics
        resulting from adding                                 The 1/N Octave filters can be used with either time signals or
                                                              narrow band spectral data.
    Condition Monitoring  plane  in turn.  The                allows  the measurement of sound  power using  either sound
        a trial mass (inertia)
                   balance
            each
        at
                                                              The  Sound  Power Analysis  scripted measurement procedure
        software guides  the
                                                              intensity probes  or microphones  according  to the international
        user
                throughout
                                                              standards ISO3744, ISO3745 and ISO9614-1.
        the entire process.
                                                              The Sound Level Meter module provides a number of analyses
        These measurements
                                                              that mimic the operation of a simple sound level meter.
        enable  influence  coefficients  to  be  calculated.  A  least  squares,
        optimized, multi-plane balancing algorithm, using a singular value
        decomposition algorithm (SVD), forms the mathematical heart of
                                                              analysis  procedures for determining  the effectiveness  of either
        the software. An option to add bias is included.      The Transmission Loss modules are automated measurement and
                                                              panels for room acoustics or pipes for exhaust mufflers.
        Once the influence coefficients are known the software predicts   The Room Acoustics Reverberation Time T60 and Total Absorption
        the masses required to achieve a zero imbalance or some user   modules  use  the  noise  source switch-off  method.  The  T60
        specified imbalance. Test runs at these conditions may be made   determination is based on a practical measurement with a decay
        giving the actual weights added to compare the predicted and
    Software  achieved results.                               The  Two-Microphone  Impedance  Measurement Tube,  (B&K
                                                              in the room of less than 60dB.
        The user interface is designed to automate repetitive testing, taking
                                                              Type 4206),  is  a  completely scripted measurement procedure
        the user through  the necessary  steps  to perform the baseline
                                                              for guiding the user in making an accurate measurement of the
        capture and trials capture. Shaft configurations, containing such
        details as balance plane name, radius, preferred trial weight and   acoustic  properties of small  material samples, it complies with
                                                              ISO10534 and ANSI E1050.
        split weight locations, may be set up and saved.
        A pre-balance run-up allows identification of the ideal shaft speed   Analysis functions included
        to perform balance. Displays include first order components for   Sound Quality Metrics  Leq with selectable time constant
        each measurement position with individual and average values.   AI Versus Time      LN Measure with S time constant
        The split weight graphical  display shows the required shaft   Loudness (Zwicker) (ISO532B)  LN Measure with F time constant
                                                                                            LN  Measure  with  selectable  time
                                                              Loudness by Stevens (ISO532A)
        positions.
    Hardware  Diagrams of standard shaft configurations are provided to enable   Nth Octave RMS Versus Time  SEL with S time constant
                                                              Loudness Versus Time
                                                                                            constant
                                                              Speech Articulation Index (ANSI S3.5 1969)
                                                                                            SEL with F time constant
                                                                                            SEL with selectable time constant
                                                              Speech Articulation Index (Vehicle Biased)
        easy set up of vehicle balancing applications.
                                                              Composite Rating Performance Value
                                                                                            Misc
                                                              High Frequency Factor
                                                                                            Nth Octave
        Features included
                                                              Preferred Speech Interference Level
                                                              Spectral Balance              Nth Octave RMS Output
                                                                                            Nth Octave Filter
        Multi-plane balancing     Primary Solution            Sound Power                   Third Octave
        Dual Tacho support for 4x4 vehicles  Refinement by Least Squares   Sound Power from Sound Pressure (ISO3744, ISO3745)  Microphone Calibration
        Split Weight calculation  Minimisation                Sound Power from Sound Intensity (ISO9614-1)   Spectrum Weighting (A,B,C,D)
        Specified Imbalance       Synchronous Resampling      Sound Level Meter             Sound Intensity
                                                                                            Difference dB Signals
                                                              rms S time constant
        Zero Imbalance
                                  Data Quality Checks
    System Packages  01-55-731  Multiplane  Balancing  Software (Requires 01-55-  Leq with S time constant  Reverberation Times
                                                              rms F time constant
                                                                                            A, B or C Weight Time Signal
                                  User Defined Level of Averaging
        Bias Factor Selection
                                                              rms I time constant (peak)
                                                                                            Impedance Tube Reflection
        SVD (Singular Value Decomposition)
                                  Standard Driveline Configurations
                                                              rms selectable time constant
                                                                                            Impedance Tube Absorption
                                                              Leq with F time constant
                                                                                            Transmission Loss through panels
                                                              Leq with I time constant (peak)
                                                                                            Transmission Loss through pipes
         DATS Multiplane Balancing Software
                                                               DATS Acoustics Analysis Suite
                                                                          Acoustics analysis suite (Requires 01-55-622
                                                               01-55-791
                    622 DATS.toolbox)
                                                                          DATS.toolbox)
   38        http://prosig.com     +1 248 443 2470 (USA)            or contact your
                                   +44 (0)1329 239925 (UK)           local representative
             sales@prosig.com
                                                                                    A CMG Company