Page 19 - MANUAL OP BENDUNG KLEPEK
P. 19
MANUAL OPERASI DAN PEMELIHARAAN
Bendung Klepek D.I. PACAL Di Kabupaten Bojonegoro
PASING CAPACITY PINTU INTAKE SALURAN INDUK PACAL KANAN
Rumus :
3
Dimana : Q = Debit (m /dt)
B = Lebar ambang (m) = 4.80 m ( 3 Pintu dibuka )
h = Tinggi air diatas ambang (m)
c = koeisien debit = 0.85
g = gravitasi = 9.80 m/det 2
z = selisih tinggi muka air di hulu & hilir pintu = 0.25 m
h Q
3
m m /dt PASING CAPACITY PINTU INTAKE SALURAN INDUK PACAL KANAN
0.00 0.00
1.60
0.30 2.71
1.50 13.55
0.35 3.16 12.95
1.40 12.64
12.50
0.40 3.61 Q = 11,60 m /dt 12.05
3
11.74
11.60
0.45 4.06 1.30 11.29
0.50 4.52 1.20 10.84
10.39
0.55 4.97 1.10 9.93
9.48
0.60 5.42 1.00 9.03
8.58
0.65 5.87 0.90 8.13
7.68
0.70 6.32 0.80 7.23
h (m)
0.75 6.77 6.77
0.70 6.32
0.80 7.23 5.87
0.60 5.42
0.85 7.68 4.97
0.50 4.52
0.90 8.13 4.06
3.61
0.95 8.58 0.40 3.16
1.00 9.03 0.30 2.71
1.05 9.48 0.20
1.10 9.93 0.10
1.15 10.39 0.00 0.00
1.20 10.84 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00
1.25 11.29 Q (m /dt)
3
1.28 11.60
1.33 12.05
1.38 12.50
1.43 12.95
1.30 11.74
1.40 12.64
1.50 13.55
Gambar 1.4-3.Pasing Capacity Pintu Intake Kanan
3
Intake Kanan terdiri dari 3 Pintu dan maksimal dapat mengalirkan debit 11.6 m /dt
dengan 3 Pintu dibuka semua.
14