Page 5 - FQ10481.CorvalGroup.MN - AlabamaFoodProcessor.DC10000S - 4000 Gal Tank
P. 5

Page No. 4
                                                                                  Proposal No. Q10481
                                                                                  Date:  April 11, 2017

                 One (1)      Set of Pump Controls Including:

                              1.     One (1) starter with NEMA Type 1 of enclosure and overloads mounted
                                     on heater.
                              2.     One (1) selector switch, mounted on the panel or starter.
                              3.     One (1) starter coil and selector switch are prewired.
                              4.     One (1) pressure gauge.
                              5.     One (1) check valve.
                              6.     One (1) pressure control switch and time delay relay to automatically
                                     activate the optional second delivery pump. (Included if optional second
                                     pump is purchased)


                 One (1)      Water Level Control Sensor Assembly Including:

                              1.     Four (4) level sensing probes.
                              2.     One (1) set of gauge cocks with plastic sight glass.
                              3.     Water wall level sensor.

                 One (1)      Water Flow Rate Assembly Including:

                              1.     One (1) pressure gauge.  (Setting rate).
                              2.     One (1) pressure actuated switch.  (Confirm flow and initiate firing).

                 One (1)      Water Make-Up Valve Including:

                              1.     Average rate solenoid operated valve.
                                     1.1  Anti-hammer diaphragm seat.

                 One (1)      Outer Wall Temperature Sensor.

                 One (1)      Water Recirculation Assembly Including:

                              1.     Temperature actuated switch - electronic signaling type.
                              2.     Recirculation water valve - solenoid operated.
                                     2.1  Anti-hammer diaphragm seat.


                 NOTE:        Water Control Valves shall be prepiped and prewired on the water heater
                              system.  The system shall be prepiped with T-304 stainless steel pipe, flanges
                              and fittings.