Note III - Customer to Provide
A. Constant minimum gas pressure to the entrance of the gas train of:
2 PSIG @ 10,000 FT /HR.
3
B. Constant water pressure to the entrance of the water heater of:
30 PSIG minimum at 230 GPM.
B.1 Ludell can furnish a booster pump with necessary controls at added
cost, if required to obtain 30 PSIG minimum constant water pressure.
C. Disconnect switches and wiring between remote valves, temperature controls
and level controls.
D. Electrical/Mechanical utility service to the heater.
D.1 Power *460 Volts, 3 Phase, 60 Hertz to blower and pump. *To be
verified by customer.
D.2 Control 115 Volts, 1 Phase, 60 Hertz to heater control panel.
E. Piping from the heater overflow to a drain.
F. Installation and hook-up of equipment prior to visit from Ludell Field
Engineer.
G. Local permits and approvals, if applicable.
Note IV - Optional Offer (Available Upon Request)
A. Ludell offers dual gas trains for use with either propane or natural gas. In
addition, various types of gas trains are available, that meet GE GAP (formerly
IRI), AGA, and CGA specifications.
B. Spare parts kit.
C. Extra stack sections.
D. Stand-by Pump and Motor Accessories.
E. Contact Ludell for pricing, if emissions under 85 ppm NOX levels are required.