Page 6 - FQ10515.GrapevineLaundryandLinens.Erie.PA.DC950-500 Gallon Tank w-Option
P. 6

Page No. 5
                                                                                Proposal No. Q10515
                                                                                Date:   June 7, 2017

               Note 1 – Ludell Field Service

                       Ludell has included in its proposal the services of our field engineer for one visit, for
                       two (2) consecutive days at no added cost.  The engineer will:  inspect the equipment for
                       proper installation, adjust controls to factory standards, verify performance guarantees,
                       and instruct your personnel on the equipment features, maintenance and operational
                       use.  It is necessary to contact the Ludell Service Department two (2) weeks prior to your
                       planned equipment start-up.  Service is scheduled to begin and end during the normal
                       work week (Monday – Friday).  Normal workday is 8 hours, any overtime will be billed
                       separately.  Weekend travel and/or short term notice start-up service will be charged at
                       additional cost.  Additional trips and service will be billed on a per diem basis, plus
                       travel and living expenses at cost.

               Note II - Ludell's Additional Features

                            A.    The Ludell Direct Contact Water Heater reduces the dissolved oxygen
                                  content of the water which is a physical law of nature when water is heated.

                            B.    The Ludell patented tangential firing provides the user with the additional
                                  feature of circular heating motion.  The circular heating eliminates surface
                                  impingement associated with the straight in firing concepts and reduces
                                  metal wall temperatures and efficiency loss.

                            C.    The Ludell burner is externally mounted to provide the user with ease of
                                  access to the valves and componentry.

                            D.    The Ludell Direct Contact Water Heater is fabricated by certified welders
                                  that perform in accordance with ASME welding procedures.  Ludell is the
                                  holder of ASME Code Stamp No. 18439.

               Note III - Customer to Provide

                            A.    Constant minimum gas pressure to the entrance of the gas train of:
                                  27” W.C. (1 psig) minimum.

                            B.    Constant water pressure to the entrance of the water heater of:
                                  35 PSIG minimum.

                            C.    Minimum/Maximum constant water flow to the heater entrance:
                                  16 GPM, 32 GPM, respectively.
   1   2   3   4   5   6   7   8   9   10   11