P. 44

Hyderabad, Chennai, Pune, Ahmedabad and Surat also have  there is a fire outbreak or another such situation that doesn't
          numerous high-rise buildings.                       allow people to leave the building. Therefore, a clear
                                                              passage must be constructed that leads to the refuge area.
          Fire risk analysis of high-rise building is of critical importance  The passage must be well-lit. It should not be used publicly
          due to the reason that there still lacks efficient systematical  and should only be used in the case of an emergency.
          fire  extinguish method to ensure a safety evacuation
          process. Super high-rise buildings are booming in the recent  It should not be an enclosed area. There shouldn't be high
          decade of years in the world, which bring challenges to fire  walls around the refuge area, although it can have a railing
          protection considering the high building density, high  or a medium-height wall to stop people from falling off. In
          occupant load and high fire load.                   the time of emergency rescue services like the fire brigade
                                                              ladder should be able to access to it without any obstruction.
          Good management of fire safety is essential to lower the  The residents of the building (or the designated authority
          probability of fire occurrence and to mitigate the consequence  responsible for the upkeep of the building) must ensure that
          if a fire does occur. It is paramount important that occupants in  the door to it must never be locked. There should be no
          the building are able to escape to a place of safety easily and  obstructions on the way to the refuge area. It should be
          quickly if a fire occurs and is out of control. The risk assessment  immediately accessible in case of an emergency. It must not
          is to identify the hazards, quantify the risk and propose measures  be used for any other purpose whether permanently or
          to mitigate and control the risk. A fire risk assessment is an  temporarily. For example, people living near the refuge
          organized and methodical review of a specific building, the  area, should not use the place for storage, cooking or
          activities carried on there and the likelihood that a fire could start  recreation purposes.
          and cause harm to the occupants and properties in and around
          the premises. The aims of the fire risk assessment are to (1)  Can there be alternative refuge areas?
          identify the fire hazards, (2) reduce the risk as low as reasonably  It depends on the height of the building. If the building has
          practicable, and (3) decide what physical fire precautions and  more than 24 floors an alternative refuge area needs be
          management arrangements are necessary to ensure the safety  provided. It must be ensured that the alternative area is
          of people in the premises if a fire does start, it can help the  built in the form of reinforced concrete cantilever projection
          building manager to decide whether any risks identified are  at the alternate mid-landing level of the staircase. The
          acceptable or need to reduce or control the risks. Firefighting at  minimum width must be 3 meters. For commercial high-rise
          great height is a tough situation where the availability of water  buildings, the minimum area for the alternative refuge area
          & people may be scared.                             must be 15 square meters and for residential buildings, it
                                                              must be at least 10 square meters. There must be a clear
          As per the National Building Code (NBC) every high-rise  passage leading to it and signs must be put up, preferably
          building or a skyscraper must have a dedicated refuge area  painted in luminous paint. It is a temporary shelter so the
          at every seventh floor of the building. The first refuge area  main staircase or the main lift shouldn't open towards the
          should be after the first 24 m (in height) and after that, every  refuge area. It is to be used only for emergencies. In high-
          seventh floor.  A building's terrace floor is also considered a  rise buildings up to 30 meters, the terrace floor of the
          refuge area. Whether it is a residential or commercial  building can be considered a refuge area. It is mandatory
          building, if it is a high-rise building, it must have a refuge  to have a fire check floor in a building that is more than 70
          area. According to NBC, buildings with nine floors and more  meters. Such a refuge area covers an entire floor every 70
          are considered to be high-rise buildings. A refuge area in a  meters. But the height of the fire check floor shouldn't
          high-rise building is designed to accommodate people in case  exceed 1.8 meters to curb misuse. It is the responsibility of
          of a fire or another emergency, especially when people are  the occupants/owners to ensure that the area is used only
          unable to leave the building. Evacuation is not possible  for the purpose of refuge and nothing else.
          sometimes. The residents or the occupants of the building
          can wait in it until help arrives.                  L.  FLOOR SPACE INDEX AND REFUGE AREA: According to
                                                                 the National building code refuge area must be limited
          Important things to remember when                      to a maximum of 4% of the total liveable area. This
          constructing refuge area in a high-rise                portion is excluded from Floor Space Index (FSI - the
                                                                 ratio of permissible built-up area). If the refuge area is
          building:                                              more than 4%, then the exceeding amount is added to
          In the building it is an emergency area to be used only when  the total liveable area.