Page 112 - Petron Plus with Price List
P. 112
TYPICAL SPECIFICATIONS:
PETRON PLUS
TM
FORMULA 7
ELECTRICAL SERVICE HYDRAULIC FLUID
————————————————————————————————–——————————————
Part No. . . . . . . . . . . . . 57320
ISO Grade, . . . . . . . . . . . . 32
Viscosity, ASTM D 445
cSt @ 40°C, . . . . . . . . . . . . 32.7
cSt @ 100°C., . . . . . . . . . . . . 6.63
Viscosity Index, ASTM D 2270, . . . . . . . . . . 164
Brookfield Viscosity ASTM D 2983, cP @ -20°C, . . . . . . . . 1090
Brookfield Viscosity ASTM D 2983, cP @ -30°C, . . . . . . . . 3360
Brookfield Viscosity ASTM D 2983, cP @ -40°C, . . . . . . . . 14240
Tapered Roller Bearing (CEC L-45-A-99), % Viscosity Loss, . . . . . . 5
Density 15°C., ASTM D 4052, kg/L, . . . . . . . . . 0.8468
Pounds per Gallon, . . . . . . . . . . . 7.044
Copper Strip Corrosion, ASTM D 130, 3 hrs @ 100°C., . . . . . . . 1B
FZG Gear Test, DIN 51354, Fail Stage, . . . . . . . . . 12
Flash Point, °F (°C), . . . . . . . . . . . 482 (250)
Pour Point, °F (°C), . . . . . . . . . . . -60 (-48)
Foam Sequence I, II, III, ASTM D 892, ml, . . . . . . . . 20/0
Dielectric Strength, kV, ASTM D 877, . . . . . . . . . 49
Acute Aquatic Toxicity (LC-50, OECD 203), . . . . . . . . Pass
Color, . . . . . . . . . . . . . Red
Meets or Exceeds the Requirements of:
DIN 51524-2: 2006-09 . . . Yes
DIN 51524-3: 2006-09 . . . Yes
ISO 11158 L-HV . . . Yes
JCMAS HK VG32W (JCMAS P 041:2004) Yes
Bosch-Rexroth RE 90220-01 . . Yes
Meets the Following Builder Approvals:
Denison HF-0 . . . . Yes
Eaton Vickers 694 (encompasses former
I-286-S, M-2950-S or M-2952-S) . . Yes
Distributed By:
December., 2013
Warranty: All products purchased from Petron Plus Global, Inc., (PPGI) are subject to terms and conditions set out in the contract, order acknowledgment and/or bill of lading. PPGI warrants only that
its product will meet those specifications designated as such herein or in other publications. All other information supplied by PPGI is considered accurate but is furnished upon the express condition
that the customer shall make its own assessment to determine the product’s suitability for a particular purpose. No warranty is expressed or implied regarding such other information, the data upon
which the same is based, or the results to be obtained from the use thereof; that any product shall be merchantable or fit for any particular purpose, or that the use of such other information or product
will not infringe any patent.