     Band and plates:-
         Band and Plates are used to attach Scaffold Tubes to Standards at 90°.
         Standards available in sizes
                                 Description                            Weight (kg)
                       Band back plate & eye bolt                            0.7
                              50 x 50 band                                   1.5
                                          Application of bracing and lacing
         Ladder beam:-
         Ladder Beams are used to construct an opening through a tempo-
         rary  structure  or  can  be  used  as  cantilevered  beams  to  support
         access scaffolding or work platforms.
         Standards available in sizes
                          Description                                              Weight (kg)
                    Ladder beam 6000 x 300                                          60.9
                    Ladder beam 4000 x 300                                          40.0
                    Ladder beam 3000 x 300                                           31.0
                    Ladder beam 2000 x 300                                          20.5