Page 131 - Hot Runner & Control Systems 2020
P. 131
Smart Series ® 128
RoHS/WEEE Compliant: Smart Series Single and
®
2-Zone Mainframe Accessories (10 AMP)
For Use With MFP1G, MFP1G1, MFPR2G, SSH1022 and SSH1021
Mold Power-Thermocouple Input Connector
ITEM A Single-Zone Power-Thermocouple Input Connector is available for mounting in or on
NUMBER the mold to accept the power-thermocouple cable from the mainframe. Water resistant,
CKPTIC1 the connector has an integral retaining latch for a secure cable connection and numbered
screw-type terminals for power and thermocouple lead wires.
*Can be mounted on top of mold for use with hot sprue bushings.
Armored Mold Power-Thermocouple Cables
ITEM
NUMBER Single-Zone Mold Power-Thermocouple Cables are constructed of special lead wire for
use in high temperature environments, and are available to connect the mainframe to the
MPTC10
connector on the mold. Available in lengths of 10 or 20 feet. Integral retaining latches
MPTC20
on the mainframe and mold connections provide secure cable connections. Connector
configurations ensure proper insertion of cable.
Replacement Connector Kits (for Controller & Cables)
MALE POWER – T/C CONNECTORS: FEMALE POWER – T/C CONNECTORS:
CKPTM1 is on MPTC10/20 Cables; CKPTF1 is on MPTC10/20 Cables;
Power Input Connectors Mates with Frame or CKPTF1L only Mates with Mold or CKPTM1L only
For Mainframe CKPTM1L Mates With CKPTF1 only CKPTF1L Mates with CKPTM1 only
MALE Smart Series ® | Smart Series Single and 2-Zone Mainframe Accessories
AC1512F CKPTM1 CKPTF1 1 5 4
3 for CKPTIC1
2
+ - and CKPTM1
or CKPTM1L
W
PTC210
AC2024F CKPTM1L CKPTF1L B
ITEM VOLTS ITEM ITEM
NUMBER NUMBER NUMBER ITEM FEMALE
AC1512F 120 CKPTM1 CKPTF1 NUMBER 5 1
PTC210
AC2024F 240 CKPTM1L CKPTF1L 4 2
3 for CKPTOC1
- + and CKPTF1
Power-Thermocouple Output Terminal Mounting or CKPTF1L
Connector (for Mainframe Bulkhead) Boxes – Prewired B
(10 AMP) 5 Pin W
ITEM
NUMBER Terminal Mounting Boxes provide the easiest and most
CKPTOC1 economical method of mounting power and thermocouple
connectors on the mold. Constructed of plated heavy gauge
steel, each box is precut and drilled for quick mounting of
ITEM NUMBER the box to the mold (2-zone, prewired terminal mounting
PTC210TBGTS box with terminal strip shown with cover plate removed).
U.S. 800-626-6653 Canada 800-387-6600 dme@milacron.com www.dme.net