text                                                    33
                                                      Stellar Systems                                         23

                    Gate Details for use with Hardened Steel (50HRC min.)




            Fig. 6   Gate Details for Standard Point Gate, High Performance Point Gate Tips
                     (SXG5110 & SXG5020) For gating onto a flat surface or into a recess* (“dimple”)




                                                                         Ø2mm/0.08in x 45°
                                                        CLEARANCE
                         5mm/.20in MIN                  DIAMETER
                            DISTANCE          R 0.25mm/  Ø19.0mm/
                            BETWEEN           0.010in MIN  0.75in              +0.005   +.0002
            Z DIMENSION    WATERLINE          R 3.00mm/                   Ø9.800mm           /.3858in –.0000
                                                                                –0.000
                            AND DROP          0.118in MAX                                +0.13  +.005
                                                                                          –0.00
                                                     90°            30°             2.03mm           /.080in –.000
                       5mm/      R0.25mm/.010in MIN
                                                                                          +0.00
                                                                                                  +.000
                      .20in MIN  R0.38mm/.015in MAX                                   2.54mm           /.100in –.005
                                                                                           –0.13
                                                                 0.13mm/.005in  0.89mm/.035in
                                     R4.76mm/.187in               MAX LAND      MAX*
                               0.62mm/.024in                  R3.18mm/.125in*
                             To Bottom of Radius
                                                           R12.70mm/.500in MIN*
                                      MIN GATE DIAMETER
                                      Ø0.71mm/.028in for un lled resins
                                      Ø1.27mm/.050in for  lled resins
                                                                                         NOTES for Figure 6 & 7:
                                                                                         1.   If gate detail does not properly
                                                                                            fit the application, contact
                                                                                            DME for assistance about
            Fig. 7   Gate Details for Sprue Gate Tips, SXT7040 & SXT7140                    gate detail options.
                                                                                         2.  Position gate detail within
                                                                                            ±0.013mm/.0005in from nominal.
                                        19.5 0.77                                        3.   The gate diameter can be
                                        SXT7140                      x 45                   opened by the customer    Stellar Systems   |    Gate Details for use with Hardened Steel (50HRC min.)

                                                                                            (The land must be re-machined
                                        19.0 0.75                   0.08                    to suit the application.
                                        SXT7040                     2              IN QUESTION  to the maximum dimension
                                                                                            after increasing the
                                                                                            gate diameter.)
                                                                                         4.  Water lines are required in “A”
                                                                                            plate for proper gate cooling.
                                                                                         5.   Position water lines as close
                                                                                            as possible but not closer than
                                                                                            the minimum distance shown to
                                                                                            provide a safe steel condition.
                                                                          Z-DIMENSION    6.   For faster color changes,
                                                                                            remove (“decone”) the
                 5 0.20                                             0.209                   resin from the front of
                   MIN                          45°                                         each point gate tip prior
                                                             30°    5.30                    to changing colors.
                                                                                         7.  The minimum “Z” dimension
                                                                                            is 13.00 and the maximum
                                                                                            “Z” dimension is 115 for point
                                                                                            gate and sprue gate tips.
                  5 0.20
                   MIN                                  10.000   +0.005  +0.0002
                                                                0.000 0.3937
                                                                          0.0000
                                                              SXT7040
                      3.30 0.130
                     MAX RUNNER                               +0.012    +0.0005
                       HEIGHT                           19.050     0.000 0.7500     0.0000
                                                              SXT7140


                U.S. 800-626-6653  n Canada 800-387-6600  n dme@milacron.com  n www.dme.net