AREAS OF APPLICATION


      Sealing of movement and construction joints in :

               Structural floor joints.
               Airport runways and apron pavements.
               Industrial warehouses.
               Chemical Plants.
               Garages & workshops.
               Water retaining structures.
               Sewage treatment plants.
               Oil and Gas Plants.
               Metal & Concrete sea walls.

       Note :  The product’s design and performance, its intended use, installation and final confirmation and approval for
               use, must be provided by the project’s Design Engineer and Project Manager.


              PHYSICAL PROPERTIES



            PROPERTIES                                               VALUES
            Colour                                                   Grey
            Density (g/cc)  - Gun Grade                              1.55 ± 0.05
                          - Pouring Grade                            1.35 ± 0.05
            Viscosity     - Gun Grade                                Thixotropic paste
                          - Pouring Grade                            Free flowing
            Shrinkage                                                Negligible
            Shore ‘A’     - Gun Grade                                20 - 35
                          - Pouring Grade                            15 - 30
            Adhesion to concrete (N)                                 >25
            Elongation (%)                                           >300
            UV resistance @300 hrs                                   No Deterioration
            Water potability (WRC)                                   Passes
            Chemical resistance                                      pH 2.5 to 11.5, hydrocarbon fuels,
                                                                     vegetable oil, urea, seawater
            Cracking & chalking after heat ageing @ 70°C             No Deterioration
            Installation time (minutes) after mixing                 <120
            Tack free time (hrs)                                     5
            Initial cure @ standard conditions (hours)               24
            Final cure @ standard conditions (days)                  7
            Application temperature (°C)                             +5 to +40
            Service temperature (°C)                                 -20 to +80


               JOINT DESIGN GEOMETRY



       The  width  of  the  joint should  be  a  minimum  of  4  times the  anticipated movement.   Joints with  cyclic
       movement should have a width to depth ratio of 2:1.  Minimum depth of the sealant should be maintained as
       recommended below :

               10mm for all porous surfaces.
               20mm for joints exposed to traffic & hydrostatic pressure.
               5mm for impervious surfaces such as metal, glass, etc.



               info@corkjoint.com   |   corkjoint.com                                                      Page 2