Page 12 - Parker - Hydraulic and Lube Filtration Products
P. 12
12AT/50AT Series
Spin-On Filters
Filter Service Accessory Parts List
Description 12AT 50AT
Filter cannisters need to be replaced
when the pressure gauge reads the Gauge - 15 psi 936911 936911
fi lter bypass setting. For example, if a Gauge - 25 psi 936912 936912
12AT fi lter has a 25 psi bypass valve, it
needs to be replaced when the Pressure switch-25 psi 926923 926923
pressure gauge reads 25 psi. If no Vacuum switch 926949 926949
indicator of any kind is used, replace Breather adapter kit 926876 926875
the cannister after the fi rst 50 hours of
operation, and every 250 hours Vacuum gauge 936909 936909
thereafter. More frequent replacement
could be required depending on
operating conditions.
Replacement Cannisters
When servicing a 12AT or 50AT fi lter,
use the following procedure: Media 12AT 50AT 50AT-2
25C 925023 926170 N/A
A. Shut down the main system and
release pressure in the fi lter line. 10C 921999 926169 927736
B. Unthread the cannister and discard 03C 926543 926541 N/A
it along with the accompanying seal. 20B 928764 928767 929446
A strap wrench may be required.
C. Apply a small amount of lubricant 10B 928763 928766 929445
to the new cannister seal. 03B N/A 934200 932073
D. Install the new cannister and hand
tighten 3/8 to 1/2 turn after gasket
makes contact with head.
Indicator Gauge (15 PSI) Indicator Gauge (25 PSI)
1.51
38.4
.36
1/8-27 NPTF 9.1
1/8 NPT
THREAD
1.58
40.1
Vacuum Switch Pressure Switch
Linear Measure = inches
mm
7