Page 145 - Parker - Hydraulic and Lube Filtration Products
P. 145
50P Series
50P-1 Element Performance
Efficiency Capacity
PSID BAR
100
Beta Rating Efficiency %
10000
2Q
5Q
2 2Q
2QQ 5Q5Q 10Q 6
80 20Q
5
99.9
1000
1 10Q
10Q0Q
60 4
200 99.5
100 99.0
20Q0Q 3
2 20Q
40
2
20 95.0
20
1
2
50.0
0 0
0 20 40 60 80 100 120
0 4 8 12 16 20
Capacity grams
Micron Size (c)
Results typical from Multi-pass tests run per test standard ISO 16889 @ 50 gpm to 100 psid terminal - 10 mg/L BUGL
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
LPM LPM
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
25 25
150SUS 150SUS
1.5 1.5
20 20
15 15
PSID 1.0 BAR PSID 1.0 BAR
Empty Housing
10 10
02Q
05Q 0.5 0.5
5 5
10Q 20Q
0.0
0.0
0 0
0 20 40 60 80 100
0 20 40 60 80 100
GPM
GPM
140