Page 161 - Parker - Hydraulic and Lube Filtration Products
P. 161
WPF Series
WPF1 Element Performance
Capacity
100
150 SUS (32 cSt)
2Q
5Q
6.0
10Q
80
5.0
60
4.0
PSID BAR
3.0
40
2.0
20
1.0
0 0.0
0 2 4 6 8
Grams
Flow vs. Pressure Drop*
LPM
0 5 10 15 20 25 30 35 40 45
30
150 SUS (32 cSt) 2.0
25
2Q
1.5
20
5Q
PSID 15 BAR
1.0
10Q
10
Empty Housing 0.5
5
0
0.0
0 3 6 9 12
GPM
*High Collapse Correction Factor:
“QH” Elements (2000 psid) = 1.4 times reported loss
Results typical from Multi-pass tests run per test standard ISO 16889 @ 10 gpm to 50 psid terminal - 10 mg/L BUGL.
Note: During reverse fl ow, ΔP is 20 psid at max. fl ow.