Page 161 - Parker - Hydraulic and Lube Filtration Products
P. 161

WPF Series


               WPF1 Element Performance





                                                                                  Capacity


                                                                    100
                                                                         150 SUS (32 cSt)
                                                                                           2Q
                                                                                           5Q
                                                                                                       6.0
                                                                                           10Q
                                                                     80
                                                                                                       5.0
                                                                     60
                                                                                                       4.0
                                                                    PSID                                  BAR
                                                                                                       3.0
                                                                     40

                                                                                                       2.0
                                                                     20
                                                                                                       1.0

                                                                     0                                 0.0
                                                                       0      2       4      6       8
                                                                                    Grams

                        Flow vs. Pressure Drop*

                                  LPM
                    0  5  10 15 20 25 30 35 40 45
                 30
                      150 SUS (32 cSt)              2.0

                 25
                                              2Q
                                                    1.5
                 20
                                                5Q
                 PSID  15                              BAR
                                                    1.0
                                              10Q
                 10
                                        Empty Housing  0.5

                  5

                  0
                                                    0.0
                    0      3       6      9      12
                                  GPM
                         *High Collapse Correction Factor:
                   “QH” Elements (2000 psid) = 1.4 times reported loss

                  Results typical from Multi-pass tests run per test standard ISO 16889 @ 10 gpm to 50 psid terminal - 10 mg/L BUGL.

                                          Note: During reverse fl ow, ΔP is 20 psid at max. fl ow.


                                                             156