Page 163 - Parker - Hydraulic and Lube Filtration Products
P. 163

WPF Series


               WPF3 Element Performance





                                                                                  Capacity


                                                                    100
                                                                         150 SUS (32 cSt)  2Q
                                                                                         5Q
                                                                                                       6.0
                                                                                         10Q
                                                                     80
                                                                                                       5.0

                                                                     60
                                                                                                       4.0
                                                                    PSID                                  BAR
                                                                                                       3.0
                                                                     40

                                                                                                       2.0
                                                                     20
                                                                                                       1.0

                                                                     0
                                                                                                       0.0
                                                                       0      10     20      30     40
                                                                                    Grams
                        Flow vs. Pressure Drop*


                                  LPM
                    0       50     100     150      200
                 30
                      150 SUS (32 cSt)              2.0


                 25
                                             2Q
                                                    1.5
                 20
                                              5Q
                                               10Q
                 PSID  15                           1.0  BAR

                                       Empty Housing
                 10


                  5                                 0.5

                  0
                                                    0.0
                    0      15     30      45     60
                                  GPM
                         *High Collapse Correction Factor:
                   “QH” Elements (2000 psid) = 1.4 times reported loss

                  Results typical from Multi-pass tests run per test standard ISO 16889 @ 45 gpm to 50 psid terminal - 10 mg/L BUGL.

                                          Note: During reverse fl ow, ΔP is 20 psid at max. fl ow.


                                                             158
   158   159   160   161   162   163   164   165   166   167   168