Page 69 - Parker - Hydraulic and Lube Filtration Products
P. 69

BGT Series








            Operating And Maintenance
            Instructions Parker Model BGT
            Tank Top Filters

            A. Mounting                       D.  Servicing Dirty Elements      F.  To Install A New Or Cleaned Element
              1. Standard mounting.               1.  Shut system down to assure that    Cartridge
                  a. Cut proper size hole in the top        there is NO PRESSURE OR FLOW        1. Lubricate all seals.
                   of the reservoir.             into     the fi lter housing.
                  b. Drill holes for studs within the                                 2. Mount new or cleaned Parker
                   proper bolt circle.            2.  Remove the fi lter cover.     fi lter         cartridge.
                  c. Set the fi lter into the cutout         3.  Remove the fi lter insert (bridge      NOTE: For ease of mounting, hold the
                   hole and secure with proper     which       holds the element in   cartridge away from the magnetic core
                   size bolts, nuts and lock       place).                         until the stud is through the hole in
                  washers.                                                         the bottom of the element.  Then slide
                                                  4.  Remove the bypass spring
                  2. Utilize proper fi ttings.    assembly           or non-        it up to securely seat it to the top of
                                                 bypass plate from the stud.       the bridge.
            B. Start-Up                                                               3. Install the bypass spring
                1.  Check for and eliminate leaks upon        5.  Remove the contaminated cartridge    assembly       or non-
                 system start-up.                  with a twisting motion.         bypass plate, and tighten until
                2.  Check differential pressure       6.  a. Discard the disposable element    snug.
              indicator, if       installed, to    cartridge.                      NOTE: Older versions may have a
              monitor element                       b. Wash cleanable or mesh      cotter pin/castellated nut retained
              condition.                         elements           in a non-      bypass spring.  In these cases, the nut
                                                 caustic solvent.  Compressed       should be turned down the shaft until
            C. Service                           air can be used to facilitate cleaning.
                1.  An element must be serviced when      Use care to prevent damage to the    the cross drilled hole is visible in the
                the indicator indicates service is      element during cleaning.   base of a castellation and the cotter
                  required.                                                        pin inserted and ends fl ared to lock
                                                 NOTE: Elements fi ner than 150     the bypass assembly in place.
              NOTE: If the fi lter is not equipped   microns (100 mesh) may require
              with an indicator, the element should   special ultrasonic cleaning. Consult         4. Re-install the insert into the
              be serviced according to machine   factory for recommendations.      fi lter      housing, making sure that
              manufacturer’s instructions.                                         the top-     spring is secure.
                                              E. Before Installing A New Element         5. Re-install the cover.  Torque the
                                                 Cartridge                            cover nuts to 22 ft./lbs.
                                                  1.  Clean the magnetic core with a lint-        Follow procedures B.1 and B.2.
                                                   free cloth.
                                                  2.  Check all seals and replace if
                                                   necessary.



























                                                             64