Page 86 - Parker - Hydraulic and Lube Filtration Products
P. 86
12CS Series
Performance
Effi ciency Capacity
Beta Rating Efficiency % PSID BAR
10000 50
2Q 3
5Q 2Q
40 5Q
1000 99.9 10Q
10Q
20Q
30 2
200 20Q 99.5
100 99.0
20
20 95.0
1
10
2 50.0
0 0
0 4 8 12 16 20 0 10 20 30 40 50
Micron Size (c) Capacity grams
Results typical from Multi-pass tests run per test standard ISO 16889 @ 15 gpm to 50 psid terminal - 10 mg/L BUGL Refer to
Appendix on pages 264-265 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
LPM LPM
0 15 30 45 60 75 90 105 0 15 30 45 60 75 90 105
25 25
150SUS(32cSt) 150SUS
150SUS
1.5 1.5
Empty Housing
Empty Housing
20 20
PSID 15 2Q 1.0 BAR PSID 15 1.0 BAR
3/4” Nominal Port Size
10 10
5Q 3/4” Nominal Port Size
0.5 0.5
10Q
5 5
20Q
0 0.0 0 0.0
0 5 10 15 20 25 30 0 5 10 15 20 25 30
GPM GPM
81