Page 87 - Parker - Hydraulic and Lube Filtration Products
P. 87
50CS Series
Performance
Effi ciency Capacity
PSID
Beta Rating e i c i f f E n c y % B A R
10000 50 2Q
5Q
2Q 5Q 10Q 3
20Q
40
10Q
1000 99.9
20Q
30 2
200 99.5
100 99.0
20
1
20 95.0
10
2 50.0
0 0
0 20 40 60 80 100
0.0 5.0 10.0 15.0 20.0 25.0 Capacity grams
Micron Size (c)
Results typical from Multi-pass tests run per test standard ISO 16889 @ 30 gpm to 50 psid terminal - 10 mg/L BUGL.
Refer to Appendix on pages 264-265 for relationship to test standard ISO 4572.
Flow vs. Pressure Loss
LPM LPM
0 30 60 90 120 150 180 210 0 30 60 90 120 150 180 210
25 25.0
150SUS (32 cSt) 150SUS
1.5 Empty Housing 1.5
20 20.0
2Q
PSID 15 1.0 PSID 15.0 1" Nominal Port Size 1 BAR
5Q BAR
10 10.0 1 1/4" Nominal PortSize
0.5 0.5
10Q
5 5.0 1 1/2" Nominal Port Size
20Q
0 0.0 0.0 0.0
0 10 20 30 40 50 60 0 10 20 30 40 50 60
GPM GPM
82